background image

7

Limited Warranty

Respironics, Inc. warrants that its mask systems (including mask frame and cushion) (the “Product”) shall be free from 

defects of workmanship and materials for a period of ninety (90) days from the date of purchase (the “Warranty Period”). 
If the Product fails under normal conditions of use during the Warranty Period and the Product is returned to 

Respironics within the Warranty Period, Respironics will replace the Product.   This warranty is non-transferable 

and only applies to the original owner of the Product.  The foregoing replacement remedy will be the sole remedy 

for breach of the foregoing warranty. This warranty does not cover damage caused by accident, misuse, abuse, 

negligence, alteration, failure to use or maintain the Product under conditions of normal use and in accordance 

with the terms of the product literature, and other defects not related to materials or workmanship.  This warranty 

does not apply to any Product that may have been repaired or altered by anyone other than Respironics. 
Respironics disclaims all liability for economic loss, loss of profits, overhead, or indirect, consequential, special 

or incidental damages which may be claimed to arise from any sale or use of the Product.  Some states do not 

allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion 

may not apply to you.
THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES.  IN ADDITION, ANY IMPLIED WARRANTY, 

INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS SPECIFICALLY 

DISCLAIMED. SOME STATES DO NOT ALLOW DISCLAIMERS OF IMPLIED WARRANTIES, SO THE ABOVE LIMITATION 

MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER 

RIGHTS, WHICH VARY FROM STATE TO STATE.
To exercise your rights under this limited warranty, contact your local authorized Respironics, Inc. dealer or 

Respironics, Inc. at 1001 Murry Ridge Lane, Murrysville, Pennsylvania 15668, 1-800-345-6443 (USA and Canada 

only) or 1-724-387-4000.

Mode d’emploi - Français-CA

Masque nasal Wisp

Usage préconisé

Le masque nasal Wisp Youth sert d’interface pour l’application d’un traitement par PPC ou à deux 

niveaux aux patients. Il est destiné à un usage unique à domicile ou à un usage multipatient dans un 

établissement hospitalier ou une institution spécialisée. Le masque est réservé aux patients âgés d’au 

moins 7 ans (> 18 kg/40 lb) auxquels un traitement par pression positive ou à deux niveaux a été prescrit.

Le masque nasal Wisp sert d’interface pour l’application d’un traitement par PPC ou à deux niveaux aux 

patients. Il est destiné à un usage unique à domicile ou à un usage multipatient dans un établissement 

hospitalier ou une institution spécialisée. Il est réservé aux patients (> 30 kg/66 lb) pour lesquels un 

traitement par PPC ou à deux niveaux a été prescrit.

 

Remarques :

 

Une valve d’expiration étant intégrée au masque, aucune valve d’expiration séparée n’est nécessaire. 

 

Ce masque n’est pas fabriqué avec du latex naturel ou du DEHP. 

Symboles

Avertissement ou mise en garde

Remarque

  Conseil

Fabriqué sans latex naturel

X1

Contrôle de résistance System One

Summary of Contents for Respironics Wisp Youth

Page 1: ...tears etc Discard and replace any components as necessary Some users may experience skin redness irritation or discomfort If this happens discontinue use and contact your healthcare professional Consult a physician or dentist if you encounter tooth gum or jaw soreness Use of a mask may aggravate an existing dental condition Consult a physician if you experience the following symptoms while using t...

Page 2: ...re At a fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on the pressure settings patient breathing pattern mask selection and the leak rate This warning applies to most types of CPAP and bi level machines At low CPAP or EPAP pressures the flow through the exhalation port may be inadequate to clear all exhaled gas from the tubing Some rebreathing may...

Page 3: ...ions Do not clean the mask with bleach alcohol solutions containing bleach or alcohol or solutions containing conditioners or moisturizers Inspect the mask for damage or wear cracking crazing tears etc Discard and replace any components as necessary Any deviation from these instructions will impact the performance of the product Institutional Disinfection For multi patient use in the hospital inst...

Page 4: ... Adjust side straps evenly f 8 Headgear Adjust bottom straps evenly g The mask should rest comfortably against face h Note Do not overtighten the headgear Using Tube Management Optional The flexible tubing may be placed over head 9 Slide the mask tubing through the headgear crown loop i before attaching the flexible tubing Using the Mask 10 Connect the flexible tubing included with the CPAP or bi ...

Page 5: ... the cushion will match the alignment cutouts of mask frame m Attaching the Elbow and Tubing Push the elbow into the cushion until the Quick Release Tabs click into place k Attaching the Headgear 1 Hold the crown strap upward 2 Make sure the wide strap marked with Philips Respironics is outward 3 Slide the headgear tabs into the longer frame arm slots 4 Connect the headgear clips to the frame or s...

Page 6: ...hieved and leak or variation in the rate of leak may affect device function Pressure Flow Curve 0 10 20 30 40 50 60 0 5 10 15 20 25 30 Flow Rate SLPM Pressure cm H2O Resistance Drop in Pressure at 50 SLPM 100 SLPM All sizes 0 8 cm H2 O 3 2 cm H2 O Deadspace Volume P 37 mL S M 49 mL L 73 mL XL adult only 85 mL Sound Levels A weighted Sound Power Level 27 dBA A weighted Sound Pressure Level at 1 m 1...

Page 7: ...ING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS SPECIFICALLY DISCLAIMED SOME STATES DO NOT ALLOW DISCLAIMERS OF IMPLIED WARRANTIES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE To exercise your rights under this limited warranty contact your local authorized Res...

Page 8: ...on Explication de l avertissement Les systèmes de PPC sont prévus pour être utilisés avec des masques spéciaux dont les connecteurs sont équipés d orifices d évacuation autorisant un flux d air continu sortant du masque Lorsque l appareil de PPC est activé et fonctionne correctement l air frais qu il envoie chasse l air expiré à travers la valve d expiration intégrée au masque Toutefois lorsque l ...

Page 9: ...isation Lavez l intégralité du masque à la main a Lavez le visage N enduisez pas vos mains ou votre visage de lotion ou de crème hydratante Procédez à une inspection du masque Remplacez le coussinet s il a durci ou s il s est déchiré Remplacez les pièces endommagées ou usées Instructions de nettoyage Au quotidien lavez à la main les pièces non textiles Toutes les semaines lavez à la main les pièce...

Page 10: ...ort aisé et confortable Avant de mettre le masque 1 Choix de la taille Sélectionnez le coussinet adapté à la largeur de votre nez sans bloquer les narines Le haut du coussinet doit se trouver entre l arête et le bout de votre nez Positionnement du masque 2 Languette ou clip du harnais Débranchez en un ou les deux b Tirez sur les languettes du harnais en les éloignant des sangles puis tirez à trave...

Page 11: ...du masque 10 Fixez le tube flexible inclus avec votre appareil de PPC ou à deux niveaux au raccord 11 Mettez l appareil de thérapie sous tension Allongez vous Respirez normalement 12 Essayez différentes positions pour dormir Trouvez la position la plus confortable En cas de fuites d air excessives procédez à des réglages supplémentaires La présence de petites fuites est normale Conseils de confort...

Page 12: ...rs l extérieur 3 Faites glisser les languettes du harnais dans les fentes du bras de coque le plus long 4 Accrochez les clips du harnais sur la coque ou faites glisser les languettes dans les fentes pour les bras de la plus petite coque si vous n utilisez pas les clips du harnais Contrôle de résistance Philips Respironics System One Lorsqu il est utilisé conjointement à un appareil Philips Respiro...

Page 13: ... l espace mort P 37 ml S M 49 ml L 73 ml XL uniquement pour adultes 85 ml Niveau sonore Niveau de puissance acoustique pondérée A 27 dBA Niveau de pression acoustique pondérée A à 1 m 19 dBA Mise au rebut Éliminez ce produit conformément aux réglementations locales Conditions d entreposage Température 20 C à 60 C 4 à 140 F Humidité relative 15 à 95 sans condensation Pression cm H2 O Débit SLPM ...

Page 14: ...t été réparé ou modifié par quiconque ne faisant pas partie du personnel de Respironics Respironics ne peut pas être tenue pour responsable des pertes économiques pertes de bénéfices coûts directs ou indirects et autres dommages consécutifs spéciaux ou accidentels susceptibles de résulter de la vente ou de l utilisation du Produit La limitation ou l exclusion de certains dommages accessoires ou co...

Page 15: ...15 ...

Page 16: ...16 1098148 R07 LZ 04 07 2015 2015 Koninklijke Philips N V All rights reserved Respironics Inc 1001 Murry Ridge Lane Murrysville PA 15668 USA ...

Reviews: