background image

Version 5: September 2010 

 

 

First Time Use: 

When using your fixture for the first time, there is a “burn in” period. Light smoke caused by the evaporation of 

assembly lubricants will be produced. This is a temporary effect that will cease when the lubricant has fully evaporated. 

 

Mounting your luminaire: 

 

A Safety Chain MUST always be used when rigging luminaires on bars, ladders etc.   
 

 

The 

Acclaim Zoomspot

 will be supplied with a safety bond accessory fitted. The safety bond is passed through 

the  luminaire  lamp-house  anchor  hole  located  at  the  rear  of  the  luminaire  and  around  the  bar.  This  is  the  only 
recommended safety bond anchor point for this luminaire.  

 

Please be careful to allow sufficient slack to allow the luminaire to be focused freely. 

 

This luminaire uses a theatre lamp with a grid filament. To avoid premature lamp failure it 
is essential that the luminaire is always mounted so the yoke is horizontal and with the 
lamp base down, i.e. the lamp adjustment knob is at the bottom of the rear lamp plate. 
 

Please  note  also  that  the  maximum  tilt  angles  of  the  luminaire  are  90º  either  side  of 
horizontal. 

 

Fitting a suspension clamp to theatre standard (48mm O.D.) pipe 

 
 
 

Your luminaire is supplied with an M12 set screw, two washers and a nut.   
 
Pass the set screw through the yoke hole from the inside, put on a washer, then the hook 
clamp, another washer and then tighten the nut.  
 
If you are not using the set screw, washers and nut, please dispose of them responsibly.  

 

To mount on a telescopic stand  

Reverse the yoke under the luminaire and bolt the stand's spigot onto the set screw.  

 

Yoke Pivot Adjustment  

 
The yoke on the  Acclaim range can be positioned anywhere in the channel that runs the length of the luminaire. This is 
useful to achieve the best balance if using a colour changer or other accessory mounted on the front of the luminaire, or to 
fit the luminaire in space restricted positions. 
 
The yoke balance point is factory set on the lamp house for normal applications.  To move the yoke, loosen the M8 bolt at 
the bottom pivot point of the yoke on the right side of the luminaire.  Release the tilt locking clamp on the left side of the 
luminaire, and slide the yoke to the required position. Check the yoke is evenly positioned on each side and tighten the M8 
bolt, and the tilt locking clamp. To return the yoke to its original balance point, align the yoke to the balance point marked 
on the focus reference scale. 
 

 

 

The luminaire should be at least 1.5m / 5ft away 
from the object it is lighting. 

The  rear  of  the  luminaire  should  be  no  closer 
than 0.6m / 2 ft away from a surface. 

 

 
 

 

 

 

Mega Clamp

Half Coupler

Hook Clamp

Washer

Bolt

Nut

Bolt

Wingnut

Bolt

Washer

Washer

1.5m/ 5 ft

0.6m /
 2 ft 

Summary of Contents for Selecon Acclaim

Page 1: ...tirely at your risk Read this manual from cover to cover before attempting installation Do not attempt installation unless you are suitably qualified If you do not understand a point in this manual don t guess Don t take short cuts If in doubt stop Contact Philips Selecon or one of its authorised distributors for advice Don t be afraid to ask for help Table of Contents Important 2 Safety Warnings ...

Page 2: ...rty Philips Selecon used all due care in preparing this manual However Philips Selecon accepts no liability for errors or omissions Philips Selecon reserves the right to change the specifications of its luminaires or the information in this manual without necessarily giving its customers notice thereof Installation operation and maintenance are entirely at the customer s risk Philips Selecon lumin...

Page 3: ...t Pass the set screw through the yoke hole from the inside put on a washer then the hook clamp another washer and then tighten the nut If you are not using the set screw washers and nut please dispose of them responsibly To mount on a telescopic stand Reverse the yoke under the luminaire and bolt the stand s spigot onto the set screw Yoke Pivot Adjustment The yoke on the Acclaim range can be posit...

Page 4: ...4 8m away and focus light to narrow angle front lens forward rear lens back To obtain sharp focus adjusts rear lens only Adjust lamp peak flat knob towards back for flattest field and forward for peaked position Reconnect the luminaire to the power supply and bring up on the dimmer Focusing your Zoomspot The variable beam of your Acclaim Zoomspot is altered by adjusting the front and rear lens in ...

Page 5: ... 44º Open the tray with the tray hanging down lift up and out to free the hinge Cleaning Reflector wipe with a soft cloth to remove accumulated dust Lens the assembly can be removed out of the luminaire clean with a soft cloth To remove baked on dust use a window cleaner Accessories Suspension Hookclamp Order Code 20HC Adjustable Iris Order Code 15ACIRIS Lens Safety Mesh Order Code 15ACSM 24º 44º ...

Page 6: ... indirect incidental special or consequential costs or damages including dismantling and re installation costs loss of operations or profits to the maximum extent permitted by law Philips Selecon accepts no liability for personal injury or property damage resulting from failure to heed relevant operating and safety procedures specified by Philips Selecon or imposed by law This is an express warran...

Page 7: ...Version 5 September 2010 7 ...

Reviews: