BDL4677XH
23
1. Press [
SET
] or [ ] button to enter the submenu.
Schedule
Today
1
2
3
4
5
7
6
2012 . 08 . 04
THU
20 : 19 : 55
On
_
:
_
_
:
_
_
Every day
Off
Input
Wed
SAT
MON
THU
SUN
TUE
FRI
Every week
2. Press [ ] or [ ] button to select a schedule item (item number 1
~ 7), and then press [ ] button to mark it the item number.
Schedule
Today
1
2
3
4
5
7
6
2012 . 08 . 04
THU
20 : 19 : 55
On
_
:
_
_
:
_
_
Every day
Off
Input
Wed
SAT
MON
THU
SUN
TUE
FRI
Every week
4
1
3
2
3. Press [ ] or [ ] button to select the schedule:
1
Power-on
schedule: Press [ ] or [ ] button to set the hour
and minute for the display to turn on.
2
Power-off
schedule: Press [ ] or [ ] button to set the hour
and minute for the display to turn off.
Select or leave an empty “
__
” for both the hour and minute slot if
you do not want to use this power-on or power-off schedule.
3
Input-source
selection: Press [ ] or [ ] button to select an
input source. If no input source is selected, the input source
will remain the same as last selected.
4
Date
schedule: Press [ ] button to select which day in a
week this schedule item will be take effect, and then press the
[
SET
] button.
4. For additional schedule settings, press [
EXIT
], then repeat the steps
above. A check mark in the box next to the number of the schedule
item indicates that the selected schedule is in effect.
NOTES:
• The {
Every day
} selection in a schedule item takes priority over the
other weekly schedules.
• If the schedules overlap, the scheduled power-on time takes priority
over scheduled power-off time.
• If there are two schedule items programmed for the same time, the
highest numbered schedule takes priority. For example, if schedule
items #1 and #2 both set the display to power on at 7:00 AM and
off at 5:00 PM, then only schedule item # 1 will take effect.
Monitor ID
Set the ID number for controlling the display via the RS232C
connection. Each display must have a unique ID number when multiple
sets of this display are connected. Monitor ID number range is between
1 to 255.
The option are: {
Monitor group
} / {
Tiling matrix
} / {
Auto ID
}
Monitor ID
Monitor ID
Monitor group
Tiling matrix
Auto ID
1
1
1
End
• {
Monitor group
}
The option are: {
Off
} / {
1-254
}
• {
Off
} – {
Monitor group
} are not supported.
• {
1-254
} – {
Monitor group
} are supported. The default setting
is 1.
• {Tiling matrix}:
Tiling matrix number range is between 1 to 15. 1 is default setting.
The {
Auto ID
} setup function enables setting up {
Monitor ID
} of
connected machine according to {
Tiling matrix
} settings.
Example: Tiling matrix sets as 4
1
2
5
6
3
4
7
8
9
10
11
12
13
14
15
16
• {Auto ID}
The option are: {
Start
} / {
End
}. The default is {
End
}.
• Switch to Start option to set up IDs of machines backward
from current one.
• Once the setup is completed, the option exits to End
automatically.
• To use this function, serial connect all machines with RS-232
cable and set their Control ports to RS-232 too.