background image

Average

Rated

Std.

Color

Color

Nominal

Average

Approx.

Product

Nominal

Pkg.

Temp.

Rendering

Length

Life

Initial

Design

Number

Description

Watts

Bulb

Base

Qty.

(Kelvin)

(CRI)

(in)

(hrs)

1

Lumens

2,3

Lumens

4

23077-1

F14T5/830/ALTO

14

T5

Min. Bipin

40

3000K

85         

22

20,000

1350

1275

23079-7

F14T5/835/ALTO

14

T5

Min. Bipin

40

3500K

85

22

20,000

1350

1275

23080-5

F14T5/841/ALTO

14

T5

Min. Bipin

40

4100K

85

22

20,000

1350

1275

23081-3

F21T5/830/ALTO

21

T5

Min. Bipin

40

3000K

85

34

20,000

2100

2000

23082-1

F21T5/835/ALTO

21

T5

Min. Bipin

40

3500K

85

34

20,000

2100

2000

23083-9

F21T5/841/ALTO

21

T5

Min. Bipin

40

4100K

85

34

20,000

2100

2000

23084-7

F28T5/830/ALTO

28

T5

Min. Bipin

40

3000K

85

46

20,000

2900

2750

23085-4

F28T5/835/ALTO

28

T5

Min. Bipin

40

3500K

85

46

20,000

2900

2750

23086-2

F28T5/841/ALTO

28

T5

Min. Bipin

40

4100K

85

46

20,000

2900

2750

23088-8

F35T5/830

35

T5

Min. Bipin

40

3000K

85

58

20,000

3650

3450

23091-2

F35T5/835

35

T5

Min. Bipin

40

3500K

85

58

20,000

3650

3450

23095-3

F35T5/841

35

T5

Min. Bipin

40

4100K

85

58

20,000

3650

3450

1) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently,
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.
3) For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp. The ballast factor is a multiplier

applied to the designated lamp lumen output.

4) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.

SILHOUETTE

T5 Fluorescent Lamps 

featuring ALTO

®

Lamp Technology

Electrical,Technical and Ordering Data 

(Subject to change without notice)

A

MAX.

 O

.D

.

17.0 mm

.67 in.

B

C

Lamp Dimensions 

inches

mm

inches

mm

inches

mm

inches

mm

F14T5

21.61

549.0

21.80

553.7

21.89

556.1

22.17

563.2

F21T5

33.42

849.0

33.61

853.7

33.70

856.1

33.98

863.2

F28T5

45.24

1149.0

45.42

1153.7

45.52

1156.1

45.80

1163.2

F35T5

57.05

1449.0

57.23

1453.7

57.33

1456.1

57.61

1463.2

A

B

B

C

MAX.

MIN.

MAX.

MAX.

Lamp 
Type

Spectral Power Distribution

400

450

500

600

550

650

700

100

80

60

40

20

0

Relativ

e

 Energ

y

Wavelength (Nanometers)

Spectral Power Distribution – TL830

400

450

500

600

550

650

700

100

80

60

40

20

0

Relativ

e

 Energ

y

Wavelength (Nanometers)

Spectral Power Distribution – TL835

400

450

500

600

550

650

700

100

80

60

40

20

0

Relativ

e

 Energ

y

Wavelength (Nanometers)

Spectral Power Distribution – TL841

Philips Lighting Company 
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation 

Printed in the USA 12/05

P-5123-D

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050  

A Division of Philips Electronics Ltd.

www.philips.com

Silho

u

ette

 T5  L

um

e

n

s vs.  A

m

bie

n

t Te

m

perat

u

re

L

um

e

n

 O

u

tp

u

t (%)

 A

m

bie

n

t Te

m

perat

u

re (°C)

10

15

20

25

30

35

40

45

50

55

5

10

20

30

40

50

60

70

80

90

100

110

0

T5

T8

102

100

98

96

94

92

90

0

5000

10000

15000

20000

25000

30000

Li

g

ht O

u

tp

u

t (%)

La

m

p Operati

ng

 Ho

u

rs

E

n

er

g

y L

um

e

n

 Mai

n

te

n

a

n

ce 

T5/HO — 2004

Reviews: