background image

5-7

A2

A1

E1

H1

H2

H3

H4

E2

C1

D1

F2

F1

G1

G3

B1

G2

16

12

25

2

6

7

26

9

11

5

27

13

28

8

1

3

18

21

20

10

24

4

22

15

23

14

17

19

59

Summary of Contents for SpeedCare GC6615

Page 1: ... Hose storage compartment Cord freedom swivel 180 degree cord freedom Hose length 1 6 m Power cord length 1 8 m Calc management Suitable for tap water Calc clean solution Smart Calc Clean Calc clean reminder Filtered water recommended Safety Information This product meets the requirements regarding interference suppression on radio and TV After the product has been repaired it should function prop...

Page 2: ...emove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Fig 1 Thermistor is part of the Power PBCA Asm ...

Page 3: ...ASSY 42 CORD CLAMP 45 CORD BOX COVER 50 TERMINAL BLOCK 46 SWITCH BRAKET ROCKER SWITCH 47 POWER CORD ASM 52 Remove SCREW CAP 57 Remove Screws A1 A2 Remove SILICON CUSHION 56 Remove INSULATION BASE 55 Remove Screws C1 C2 C3 C4 C5 C6 C7 Remove UNIT BASE COVER 51 Remove BOTTOM FOOT 40 Remove Screws D1 D2 D3 D4 D5 D6 D7 Remove WATER TANK ASM 36 Remove UNIT BASE BODY 43 Remove Screw E1 E2 Remove PUMP BR...

Page 4: ...y ber tube Throat clamp Bend connector Throat clip Potentiometer box Cord clamp Dial knob Top cover Cord bushing Power PCB box Power PCB asm Silicon pad Switch hole cover Button Connection wire asm Wire connector Iron base support Pos Service code Description N A N A N A N A N A Release button Lock fastener Location fastener Bolt base Water tank asm Seal ring Water tube connector Silicon tube Bott...

Page 5: ...5 7 A2 A1 E1 H1 H2 H3 H4 E2 C1 D1 F2 F1 G1 G3 B1 G2 16 12 25 2 6 7 26 9 11 5 27 13 28 8 1 3 18 21 20 10 24 4 22 15 23 14 17 19 59 ...

Page 6: ...GC6615 6 7 A2 C1 C2 C6 G1 H1 E1 D1 D2 D4 D5 D3 D6 D8 D7 E2 F1 F2 F4 F3 I1 I2 A1 C3 C5 C7 C4 38 42 44 34 35 36 43 37 41 33 32 31 57 52 55 45 50 49 47 40 46 39 58 51 48 56 Exploded view Stand ...

Page 7: ...Deg C Materials for example Test point Minimum Maximum 120 143 All fabric types 2 Leakage current Check that leakage current is within IEC requirement Measure leakage current between LIVE NEUTRAL EARTH IEC requirement is that at 230 V supply the EARTH leakage current must be less than 0 75 mA 3 Water leakage Functionality Check that there is no water leakage from any part of product during operati...

Reviews: