7-7
•
Due to the high wattage of the iron, only the
cord set must be used.
•
Should damage be observed on the
, it must be replaced.
•
Continued usage is not allowed.
•
If
is provided without type plate information eg. Type number, voltage etc. When replacing the cover,
engrave the type number & voltage on the type plate with a sharp object.
•
After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulation
as laid do
ally established at this moment.
•
The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.
Check the soleplate temperature is within IEC requirement.
Soleplate temperature ( Deg C)
Materials, for example
Test-
point
=
=
Minimum
Maximum
Check that leakage current is within IEC requirement.
Measure leakage current between LIVE/NEUTRAL & EARTH.
Check that there is no water leakage from any part of product during operation.
Check that the functionality of the product (product dependent) eg. Steaming, steam trigger, variable steam, SOS, PCBA
etc is working properly.
Check that there are no loose parts eg. Extra screws in
When replacing fuse, to also service the water tubes which is probably choked with calc.
All failed PCBAs including to be packed with ESD bags for shipment.
ned screws in terms of length and material used.
Repair Instruction
The torque of the thermistor-soleplate screw is 9-12kg f.cm.
230
170