background image

45$"GP
%GGLDCAQGML4LGQ

P1

indoor

50Hz

60Hz

220V

240V

Max.

40 °C

Min.

°C

89&$

DVE

1/5

Type Desc 

Power 

Lamp 

Lamp 

Holder 

Ballast 

Shading cloth 

 

UVCA200 EU

UVCA200 UKI

120W 

4×TUV PL-L 18W

 

9279 030 04007

2G11 

HF-P218/236

 

9114 018 21890 

9114 018 20890 

12.3 

UV-C wavelength: 254nm

 

1 – Control panel 

2 – Air outlet 

3 – Body 

4 – Air inlet 

5 – Timing 

6 – Fan speed light 

7 – UV working light 

8 – Power switch 

9 – Lock 

10 – Timing switch 

11 – Fan speed control 

Operation 

1. Plug in 

Plug in the power cord, power the machine, the buzzer will beep, at the same time, the power key indicator is always on, indicating the success of power.

2. Power on/off 

Power on: touch the power on key to start the machine when it is off. Default display mode is: 

A. The fan speed indicator is on 2/3, and the fan speed is in gear 2;

B. The UV indicator is on and the UV lamp is in working state;

C. The time indicator is "060", indicating that the disinfection time is 60 minutes, and the machine will automatically shut down after 60 minutes. 

Power off: to shut down the product before disinfection duration is finished, please press the power switch button. Only the power indicator will remain on

while all the rest will turn off with notification tone. 

3. Fan Speed Button 

Press fan speed button to select the fan speed, 1 (low speed), /2 (medium speed), /3 (Max speed). The product starts quickly and smoothly and can reach the 

maximum air volume within 20 seconds (if set to the maximum speed).  

4. Timing Settings 

Press Timer button to select disinfection duration, ON-30min-60min-120min as a cycle.

5. Lock 

Long press the lock key above 3s, and the lock indicator light will always be on, indicating that the lock mode has started. At this point, pressing any key is 

invalid (the lock indicator will flash 3 times when pressing any key). Long press the lock key above 3s to exit the lock mode. You can also exit the lock mode by

removing the power or when disinfection duration is finished.

1

2

4

5
6
7

8
9

10

11 

© 2021, Signify Holding All rights reserved 

UKI

EU

OR

12NC

9114 015 48581
9114 015 48681

Summary of Contents for UVCA200

Page 1: ...inutes and the machine will automatically shutdown after 60 minutes Power off to shut down the product before disinfection duration is finished please press the power switch button Only the power indicator will remain on while all the rest will turn off with notification tone 3 Fan Speed Button Press fan speed button to select the fan speed 1 low speed 2 medium speed 3 Max speed The product starts...

Page 2: ...ical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Lamp Ballast Shading cloth replacement 1 Only those who have received instruction training can replace the relevant par...

Page 3: ...g cloth Wrap the new shading cloth on the iron barrel and double ensure it s not possible for lighting leakage 1 power off 2 loose screw 3 remove front cover 1 disconnect the internal power wires 2 disconnect the internal power wires 3 remove the UVC lighting cavity out Remove the screws of lamp holder replace lamp Assemble back Caution double ensure the shading cloth is fixed correctly Change dri...

Page 4: ...he bag vacuum debris and any materials used to clean the vacuum in a plastic bag 5 Promptly place all bulb debris and cleanup materials including vacuum cleaner bags outdoors in a trash container or protected area until materials can be disposed of Avoid leaving any bulb fragments or cleanup materials indoors 6 Next check with your local government about disposal requirements in your area because ...

Page 5: ...QIRUPDWLRQ LQFOXGHG KHUHLQ LV JLYHQ DQG DQ OLDELOLW IRU DQ DFWLRQ LQ UHOLDQFH WKHUHRQ LV GLVFODLPHG 7KH LQIRUPDWLRQ SUHVHQWHG LQ WKLV GRFXPHQW LV QRW LQWHQGHG DV DQ FRPPHUFLDO RIIHU DQG GRHV QRW IRUP SDUW RI DQ TXRWDWLRQ RU FRQWUDFW 3KLOLSV DQG WKH 3KLOLSV 6KLHOG PEOHP DUH UHJLVWHUHG WUDGHPDUNV RI RQLQNOLMNH 3KLOLSV 1 9 OO RWKHU WUDGHPDUNV DUH RZQHG E 6LJQLI ROGLQJ RU WKHLU UHVSHFWLYH RZQHUV 6LJQL...