M
AINTENANCE
:
2
0 2 . 9 6 8 5 . 0 0 1 0 A
21-May-2009
69
AC Input (PowerCon) Connector Replacement
Parts:
25.9685.0756
1 EA
CONNECTOR, AC INPUT (POWERCON)
Tools:
•
#2 Phillips Screwdriver
WARNING:
Remove power from luminaire before performing maintenance.
To remove and replace AC input (PowerCon) connector:
Step
1. Remove power from luminaire.
Step
2. Position light to access top of pan tube assembly.
Step
3. As shown in
Figure 36
, at pan tube cover, remove six 8-32x1/2" PFB screws.
Step
4. Remove pan tube cover. (Note, tether will still hold cover).
Figure 36: AC Input (PowerCon) Connector Replacement
Step
5. Remove two 4-40x1/2" PFB screws at front of PowerCon.
Step
6. Disconnect wiring from PowerCon.
Step
7. Replace PowerCon by performing Steps 3 through 6 in reverse.
AC Input (PowerCon) Connector
Some components not
NOTE:
Pan Tube Cover
8-32x1/2" PFB
Cover Tether
Pan Tube Assembly
shown for clarity. This
4-40x1/2" PFB
Screws (x2)
Screws (x6)
procedure is applicable
for all models.
VL500 80V
Pan Tube Assembly
Do not remove this screw
Summary of Contents for Vari-Lite VL500
Page 1: ......
Page 13: ...SAFETY NOTICE JAPANESE 02 9685 0010 A 21 May 2009 xiii ...
Page 14: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL xiv 21 May 2009 02 9685 0010 A ...
Page 34: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 16 21 May 2009 02 9685 0010 A Notes ...
Page 118: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 100 21 May 2009 02 9685 0010 A Notes ...
Page 168: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 150 21 May 2009 02 9685 0010 A Notes ...
Page 212: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 194 21 May 2009 02 9685 0010 A Notes ...
Page 218: ...VARI LITE VL500 LUMINAIRE SERVICE MANUAL 200 21 May 2009 02 9685 0010 A Notes ...
Page 219: ......