Reflector Removal
WARNING:
Ensure that power is completely removed (disconnected) from luminaire before
attempting any work. Wear protection on hands (soft cotton gloves) when handling glass.
To remove reflector assembly:
Step
1. Remove power from luminaire and allow unit to completely cool.
Step
2. Remove rear cover assembly as described in
“Rear Cover Assembly Removal” on page 20
Step
3. Loosen two quarter-turn Dzus rapier fasteners from lamp house cover and remove lamp.
Figure 2-29: Lamp Socket Cover Removal
Step
4. Remove one 6-32 x 3/8" PPZ SEMS screw and flat washer and detach lamp cover tether
from fixture.
Step
5. As shown in
a.
Remove two 8-32 x 5/8" PPZ SEMS screw (1 per side) at counter weight plate, closest
to rear of assembly.
b. Note, the counter weight plates will stay attached by 2 screws closest to inside of fixture.
Step
6. Remove two 6-32 x 3/8" PPZ SEMS screws from rear of assembly, closest to L1 & L2 fans.
Lamp Socket
Lamp
Cover
Lamp Socket
Quarter-Turn
Fasteners
Summary of Contents for Vari-Lite VL770
Page 1: ......
Page 13: ...FOREWORD 02 9687 0010 0 xi ...
Page 14: ...VARI LITE VL440 VL770 VL880 SPOT LUMINAIRES SERVICE MANUAL xii 02 9687 0010 0 ...
Page 30: ...VARI LITE VL440 VL770 VL880 SPOT LUMINAIRES SERVICE MANUAL 12 02 9687 0010 0 Notes ...
Page 156: ...VARI LITE VL440 VL770 VL880 SPOT LUMINAIRES SERVICE MANUAL 138 02 9687 0010 0 Notes ...
Page 164: ...VARI LITE VL440 VL770 VL880 SPOT LUMINAIRES SERVICE MANUAL 146 02 9687 0010 0 Notes ...
Page 188: ...VARI LITE VL440 VL770 VL880 SPOT LUMINAIRES SERVICE MANUAL 170 02 9687 0010 0 Notes ...
Page 189: ......