OUT TO SUPPLY WIRES
SEE NOTE 3
STREET SIDE LABEL
SEE NOTE 5
POLE FASTENERS
SEE NOTES 2 & 6
INSTALLATION:
1)
TURN POWER OFF.
2) Loosen pole fasteners on pod, if required.
3) Make fixture wiring connections to supply wires (by others)
- White to White
- Black to Black
- Green to Green
NOTE:
Both green ground wires from fixture should be
"bugged" together with incoming supply wire.
4) Slip luminaire post fitter onto pole and ensure wires
are not being pinched.
5) Orient by turning luminaire "street side" via label
supplied on globe fitter (pod).
6) Torque pole fasteners as follows to 7 ft. lbs.
CAUTION!
Over torquing of screws may lead to
damage or fatique of fastener.
7) Power to luminaire may now be turned on.
32002016, revision A
INSTALLATION INSTRUCTIONS:
VL71 & VL72
(Fixture)
SAFETY WARNING:
ALWAYS TURN FIXTURE OFF/DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
Ensure that the AC service is OFF before any installation or maintenance.
Do not switch service to ON until the entire installation is complete.
Philips Lighting Company
200 Franklin Square Drive
Somerset, NJ 08873
Phone (US): 855-486-2216
Phone (CAN): 800-668-9008
TOOLS REQUIRED:
-5/32" Allen Wrench/Driver
-Torque Wrench capable of 7 ft. lbs. torque
This fixture is intended for installation in accordance with the National Electrical Code and local code
specifications. Failure to adhere to these codes and instructions may result in serious injury and/or damage to
the fixture components and void the warranty. These instructions do not purport to cover all details or vairations
in equipment, nor to provide for every possible contingency related to installation, operation, maintenance, or
mounting situation. Should specific problems occur that are not addressed by these instructions, contact your
Sales Representative or distributor for assistance. Retain these instructions for future reference.