51
EN
EN
EN
EN
3.1
Description of optional features
1 Door Unlock Impulse
Duration of unlocking impulse.
2 Door Lock Impulse
Duration of locking impulse.
3 Dome Light Delay
Time after arming, when sensors are inactive. During this time LED is constantly ON.
4 Alarm Limitation Number
The system enables to limit maximum alarms triggered consequently by one sensor. When
number of alarms will reach this limit, specific input will be by-passed. But if the alarm is
triggered by other input, sensor is activated again.
5 Sound of Siren
To differentiate your car from others, you can choose different type of siren sound.
6 Last Door Arming Delay
Time since turning ignition off and closing all doors to arming the system. When door is
opened during this time, countdown is reseted.
7 Door Lock With Last Door Arming
This option specifies if door should be locked when system is armed by Last Door Arming.
8 Hazard Lights Output
If connection to car’s head light is too difficult or impossible, you can connect to direction
lights via hazard light switch (see figure 6). Regarding to system of control hazard lights, you
can choose one of two available modes: continuous (Mode 1) or pulse (Mode 2).
Example:Signal lights flash 4 time
9 Trunk Release Impulse
Duration of positive impulse for trunk output.
10 AUX Impulse
Duration of negative impulse for AUX output.
11 Arming / Disarming Chirp
This option enables or disables audio signal (siren chirp) on arming / disarming.
System light output
Vehicle hazard lights
Mode1
Mode 2
Continual sound
Intermittent – Type 1
Intermittent – Type 2
Intermittent – Type 3