Undervoltage
---
---
Switches off
Over temperature
Reduces the charging current if over temperature occurs and switches off the load if the temperature reaches a high
level.
(1) Panels are short circuited by diodes. The controller can therefor only be subjected to these conditions for a limited time. A Battery connected to the
panel terminals in reverse polarity will instantly cause a damage to the controller.
(2) A battery fuse is necessary to protect the CIS-MPPT from getting damaged by reverse polarity connection on the battery terminals.
(3) Controller can protect itself, but any connected loads might be damaged.
(4) Short circuit: >3x – 20x nominal current.
(5) Battery must be protected by a fuse, or it might be permanently damaged in case of short circuit.
(6) >200% nominal current: disconnects with 3s delay,
>150% nominal current: disconnects with 10s delay,
>110% nominal current: disconnects with 120s delay.
(7) MPPT switches off when detecting reverse current.
(8) At voltages above 50 V the MPPT will stop charging.
WARNING:
The combination of different error conditions may cause damage to the controller. Always remove the fault condition before you continue
with connecting the controller!
Low Voltage Disconnect Function (LVD)
State of charge controlled (SOC): Disconnect at
11.00/22.00 V to 11.70/23.40 V(SOC1), 11.12/22.24 V to 11.76/23.52 V(SOC2),
11.25/22.50 V to 11.83/23.63 V(SOC3), 11.38/22.72 V to 11.89/23.78 V(SOC4),
11.51/23.02 V to 11.96/23.92 V(SOC5), 11.64/23.28 V to 12.02/24.04 V(SOC6).
Voltage controlled (LVD): Disconnects at a fixed voltage between 11.0/22.0 V and 11.9/23.8 V (voltage steps 0.1/0.2 V).
Note:
Battery voltage must be below adjusted setting for longer than 2 minutes for before LVD occurs.
Note:
Voltage levels before/after the slash are valid for 12 V and 24 V systems respectively (valid for the charge controllers presented in this manual).
20
Summary of Contents for CIS-MPPT 50/10
Page 6: ...4 Zum Kontroll Dimm Steuer eingang der LED Treiber Erdungs Stelle Sich erung...
Page 18: ...16 Connect to dimming control terminal of LED Driver Grounding post Fuse...
Page 42: ...40 Connectez au terminal de contr le du gradateur du pilote LED Mise la terre Fusi ble...
Page 54: ...52 Conecte ao terminal de controle de luminosidade do LED Driver Ponto de aterramento Fus vel...
Page 63: ...CIS MPPT 50 10 IP68 1 5 m 72 CIS CU 4 3 12 24 V CIS MPPT 50 10 61...
Page 64: ...CE CE MPPT 98 IP68 40 C 60 C 62...
Page 66: ...64...
Page 67: ...CIS MPPT 50 10 3 65...
Page 68: ...0 V 10 V 1 V 1000 Ohm CIS CU 1 CIS CU 2 N A 10 V 0 V 66...
Page 71: ...8 0 16 0 V 1 0 h 0 h 0 h 0 h 50 1 1 5 3 0 V 69...
Page 74: ...20140715 Phocos AG Germany www phocos com 72 ISO9001 RoHS...