No dimming
Dimming is on
Load off
Load hours
on
on
off
Dimming hours
on
off
N/A
Dimming output voltage
10 V
Voltage proportional to
adjusted dimming value
0 V
Corresponding relationship of 'Output voltage' and 'Dimming value'
Output voltage
0 V
1 V
2 V
3 V
4 V
5 V
6 V
7 V
8 V
9 V
10 V
Dimming value*
0%
10%
20% 30%
40%
50%
60%
70%
80%
90%
100%
* : +/- 3% tolerance
Testing Function
Pushing the test button on the CIS-CU (Control Unit) will switch on load terminal for 1 minute.
Should pressing the button cause a load disconnect event (LVD/SOC, over current) than the load will be
switched off immediately.
Safety Features
PV terminal
Battery terminal
Load terminal
Reverse polarity
Protected (1)
Protected
Protected (2)
Short circuit (3)
Protected
Protected (4)
Switches off immediately
Over current
Limited
---
Switches off with a delay (5)
22