The two voltage levels before/ after the slash are valid for 12 V and 24 V systems
respectively.
To find the right value, we recommend measuring the solar array open circuit
voltage at the time when twilight has reached the level when the controller
should switch on/off. This value (the closest available) can then be set according
to the description in the programming section.
37
Switching off the Acoustic Signal
The controller has an acoustic signal which indicates the change of the state of
charge. This function can be deactivated in Programming Menu 7.
7.7/15.4V
4.9/9.8V
(Factory-
setting)
1.0/2.0V
Threshold setting range
Switching point day>Night
Curve of open-circuit voltage solar array
Switching point Night>day