25
Mounting and Connecting the Charge Controller
for functions of datalogger.
The charge controller has a number of safety and display functions.
The controller is intended for indoor use only. Protect it from direct sunlight and
place it in a dry environment. Never install it in humid rooms (like bathrooms).
The controller measures the ambient temperature to adopt the charging voltage,
therefore it must be installed in the same room as the battery.
The controller warms up during operation. It shall be installed on a non flammable
surface only.
Recommendations for Use
The controller warms up during normal operation. If there is insufficient
ventilation (e.g. in an installation cabinet), the controller limits the solar
charge current to prevent overheating.
The controller does not need any maintenance or service. Remove dust with
a dry tissue.
It is important that the battery gets fully charged frequently (at least monthly).
Otherwise the battery will be permanently damaged.
A battery can only be fully charged if not too much energy is drawn during
charging. Keep that in mind, especially if you install additional loads.
Summary of Contents for CXN Series
Page 1: ...Phocos CXN CID NO 181811101...
Page 2: ...1 22 23 44 45 66 67 88 89 110 111 132 CONTENTS...
Page 118: ...Phocos CXN 111...
Page 119: ...112...
Page 120: ...113...
Page 121: ...114...
Page 122: ...115...
Page 123: ...116...
Page 124: ...117...
Page 125: ...118...
Page 126: ...119...
Page 127: ...120 80 60 80 35 60 10 35 10 1x 2x 3x 4x 5x...
Page 128: ...121...
Page 129: ...122...
Page 130: ...123 1 2 1 2...
Page 131: ...124 7 7 15 4V 4 9 9 8V 1 0 2 0V...
Page 132: ...125...
Page 133: ...126...
Page 134: ...127...
Page 135: ...128...
Page 136: ...129...
Page 137: ...130...
Page 138: ...131...
Page 139: ...132 RoHS ISO9001 2000...