Dear Customer,
Congratulations on buying your Phocos product! Please read the instructions carefully and
thoroughly before using the product. Your new CXNup controller is a “state-of-the-art” device
which was developed in accordance with the latest available technical standards. It comes with
a number of outstanding features, such as:
User friendly LCD showing extensive system information
Four-stage PWM charging algorithm with integrated temperature compensation for lead
battery and two stage charge algorithm for LiFePO4 battery
Full electronic protection
Programmable nightlight function
USB charging port
Datalogger information which can also be exported
Load status indication
Touch keys ensuring long lasting operation
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions for CXNup controller that shall be followed during
installation, operation and maintenance of the charge controller.
RISK OF FIRE: ATTACH THE TEMPERATURE SENSOR TO THE BATTERY.
Battery type: Lead acid (GEL, AGM, flooded), LiFePO4
Nominal voltage rating of the battery: 12 or 24 V
Battery fuse: Use a fast acting fuse with an interruption rating capacity of 1000 A on the battery
side. We recommend to use a fast acting melting fuse (e. g. car type fuses) as close as possible
to the battery terminal. The maximum current rating should be 1.5 times of the nominal current
of the charge controller. Respect the maximum current rating of the BMS when using LiFePO4
batteries.
Please do not disassemble or attempt to repair Phocos products. Phocos charge controllers do
22
Summary of Contents for CXNup
Page 14: ...11 Loc Men Sperren der Einstellungen YES Ja NO Nein 12...
Page 22: ...20 CXNup sicherer Betriebsbereich SOA Nennlaststrom...
Page 27: ...25 USB charging connector Interface for MXI MXI232 Temperature sensor NTC connector...
Page 34: ...32...
Page 42: ...40 CXNup Safe Operating Area SOA...
Page 47: ...45 Conector USB de carga Interfaz para MXI MXI232 Sensor de temperatura Conector NTC Fusi ble...
Page 55: ...53...
Page 76: ...11 Menu Loc Verrouillage des param tres YES oui NO non 74...
Page 84: ...82 Aire de s curit CXNup SOA Courant nominal charge...
Page 97: ...95...
Page 105: ...103 CXNup rea de prote o segura SOA Corrente de carga nominal...
Page 107: ...CXNup LCD PWM USB MP3 CXNup GEL AGM LiFePO4 12 24 V 1 5 LiFePO4 BMS 105...
Page 108: ...CE CE 12 V 24 V 106...
Page 110: ...108 NTC MXI232 MXI USB...
Page 111: ...12 V 24 V 18 V 24 V LCD 109...
Page 112: ...110 LCD ESC DOWN UP SET...
Page 113: ...LVD C PWM SET DOWN UP 111...
Page 114: ...90 70 90 30 70 10 30 0 10 0 25 1 112...
Page 117: ...11 Loc YES NO 115...
Page 118: ...1 2 3 4 50 V 50 V 15 5 31 0V 1 2 4 6 3 4 150 2 Min 200 3 s 116...
Page 120: ...15 5 31 0 V 1 118...
Page 121: ...C Err NTC 119...
Page 122: ...12 V 24V CXNup 10 CXNup 20 CXNup 40 12 24 V 10 A 20 A 40 A 10 A 20 A 40 A 120...
Page 125: ...123 CXNup SOA...