Mode 2 voltage:
Load disconnect level can be set between 11.0/22.0 V and 11.5/23.0 V. It is
appropriate if bypass loads draw current directly from the battery. This mode allows a lower
disconnection point. The battery is cycled deeper, and this can shorten battery lifetime.
Settings
The CXup has four buttons (ESC = X, DOWN, UP, = SET) to navigate through the menu and
✔
adjust the settings. By pushing the the SET ( ) button during 5 seconds you can turn the load
✔
on or off. To enter the menu, push the ESC (X) button and navigate between the 'LOG' and the
'Set' menu with the arrow buttons (UP and DOWN). To modify settings, enter the menu ‘Set’ by
pressing the SET ( )
✔
button. Navigate to the desired value with the arrow buttons (UP and
DOWN). Press the SET ( )
✔
button to modify the value (the selected value flashes). Modify the
value with the arrow buttons (UP and DOWN) and save the changes by pressing the SET ( )
✔
button again (The value flashes fast for a second to acknoledge the change) or return to the
‘Set’ menu without saving the modified value by pressing the ESC (X) button. The following
menu settings are presented by the LC display of the controller. Voltage values for 12 V systems.
For 24 V systems double voltage values.
1.
Battery Capacity 'CAP' menu: Set Battery Capacity 5 … 5000 Ah (standard:
nominal current x 10h)
2.
Battery Type 'typ' menu: set battery type 'GEL' , 'LIQ' and 'LFP' as Gel, Liquid,
LiFePO4 battery
3.
LVD mode 'Mod' menu: set LVD mode as current adapted (SOC) 'CUR' (Only
Battery Type: Gel / Liquid) or 'V' (fixed voltage)
4.
LVD menu: LVD: 11.0 V … 11.5 V (default 11.0 V) / SOC: 11.5 V … 12.0 V (default
11.9 V) (Only Battery Type: Gel / Liquid)
5.
'rSt' menu: Reset settings to factory default: YES, NO
6.
'buz' menu : Buzzer ON, OFF
7.
'NL' menu: Night Light mode: OFF, D2D, MN (Mid of Night), DD (Dusk and Dawn)
8.
'Eve' menu: Evening hours 0 h … 20 h (default 0 h)
(Only Night Light mode: Mid of Night / Dusk and Dawn)
9.
'Mor' menu: Morning hours 0 h … 20 h (default 0 h)
(Only Night Light mode: Mid of Night / Dusk and Dawn)
10.
'ND' menu: Night detection level 1.5 V … 10.0 V (default: 8.0 V)
11.
'Loc' menu: Lock settings YES, NO
30
Summary of Contents for CXup 10
Page 14: ...12...
Page 26: ...24 USB charging connector Interface for MXI MXI232 Temperature sensor NTC connector...
Page 33: ...31...
Page 40: ...38 CXup Safe Operating Area SOA...
Page 45: ...43 Conector USB de carga Interfaz para MXI MXI232 Sensor de temperatura Conector NTC Fusi ble...
Page 53: ...51...
Page 61: ...59 Zona de funcionamiento seguro de CXup SOA Corriente nominal de los consumidores...
Page 74: ...72...
Page 82: ...80 Aire de s curit CXup SOA Courant nominal charge...
Page 95: ...93...
Page 104: ...CXup LCD PWM USB MP3 CXup GEL AGM LiFePO4 12 24 V 1 5 LiFePO4 BMS 102...
Page 105: ...CE CE 12 V 24 V 103...
Page 107: ...105 NTC MXI232 MXI USB...
Page 108: ...12 V 24 V 18 V 24 V LCD 106...
Page 109: ...107 LCD ESC DOWN UP SET...
Page 110: ...LVD C PWM SET DOWN UP 108...
Page 111: ...90 70 90 30 70 10 30 0 10 0 25 1 109...
Page 114: ...112...
Page 115: ...1 2 3 4 50 V 50 V 15 5 31 0V 1 2 4 6 3 4 150 2 Min 200 3 s 113...
Page 117: ...15 5 31 0 V 1 115...
Page 118: ...C Err NTC 116...
Page 121: ...119 CXup SOA...
Page 122: ...20160518 Phocos AG Germany www phocos com 120 ISO9001 RoHS...