Starting up the controller
Self Test
As soon as the controller is supplied with power from the battery, it starts a self test routine. Then the display changes to normal operation.
System Voltage
The controller adjusts itself automatically to 12 V or 24 V system voltage. As soon as the voltage at the time of start-up exceeds 18 V, the controller
assumes a 24 V system. If the battery voltage is not within the normal operation range at start-up, a status display according to the section ERROR
DESCRIPTION occurs.
Battery Type
The ECO-N-MPPT 85/15 has no equalization charge and is therefore suitable for lead-acid batteries with liquid electrolyte (vented batteries) and lead-
acid batteries with solid electrolyte (GEL or AGM batteries). For Lithium batteries an MXI accessory is needed as well as the PhocosLink software. In
case of any doubts consult your local dealer.
LED indications & warning functions
LED
Status
Function
On
Controller connected to battery, night detected
Flash
Controller connected to battery, day detected
Off
No battery connected
On
Battery SOC low
Flash
Battery SOC very low
Off
Battery OK