(8) At voltages above 85 V the MPPT will stop charging.
WARNING:
The combination of different error conditions may cause damage to the controller. Always remove the fault condition before you
continue connecting the controller!
Low Voltage Disconnect Function (LVD)
The charge controller is equipped with a low voltage disconnection function to protect the battery against a deep discharge: This function is
controlled by the voltage, and automatically switches off the load output at a battery voltage lower than 11.0/22.0 V. As soon as the battery reaches a
voltage of 12.8/25.6 V (12.2/24.4 V for Lithium battery), the load output is switched on again.
Note:
Battery voltage must be below adjusted setting for longer than 2 minutes before LVD occurs.
Note:
Voltage levels before/after the slash are valid for 12 V and 24 V systems respectively (valid for the charge controllers presented in this manual).
Error Description
Error
Display
Reason
Remedy
Loads are not supplied with
energy
Red LED on
Battery is low
Load will reconnect as soon as
battery is recharged.
Red LED flashing
Overcurrent/Short circuit of
loads/Over temperature protect
Switch off all loads. Remove
short circuit. Controller will
switch on load automatically
after max 1 minute.
16
Summary of Contents for ECO-N-MPPT 85/15
Page 53: ...ECO N MPPT 85 15 98 IP68 IP21 60 12 24 V ECO N MPPT 85 15 51...
Page 54: ...CE CE 4 0 mm2 ECO N MPPT 85 15 MXI Phocos MXI MXI232 52...
Page 55: ...53 LED LED LED MXI...
Page 56: ...12 24 V ECO N MPPT85 15 GEL AGM MXI PhocosLink 54...
Page 57: ...1 2 3 4 5 6 7 85 V 8 85 V 15 5 31 0V 1 2 3 4 3 5 55...
Page 58: ...6 200 3 s 7 MPPT 8 85 V MPPT 11 0 22 0 V 12 8 25 6 V 12 2 24 4 V 2 12 V 24V LED LED LED 56...
Page 59: ...LED LED 15 5 V LED LED LED 57...