background image

 Liability Exclusion

The manufacturer shall not be liable for damages, especially on the battery, caused
by   other   use   than   as   intended   or   as   mentioned   in   this   manual   or   if   the
recommendations of the battery manufacturer are neglected. The manufacturer shall
not be liable if there has been service or repair carried out by any unauthorized
person, unusual use, wrong installation, or bad system design.

Specifications are subject to change without notice.
Version: 20190122
Made in China

Phocos AG
Magirus-Deutz-Str. 12
89077 Ulm, Germany
Phone +49 731 9380688-0
Fax +49 731 9380688-50
www.phocos.com
info@phocos.com

20

ISO9001

RoHS

Summary of Contents for ECO-N

Page 1: ...Phocos ECO N Solar charge controller Betriebsanleitung User Manual Manual del usuario Manuel de l utilisateur Manual do Usu rio CID 181820310...

Page 2: ...es to the charge controller Please verify that all cable wire connections are done properly and well insulated and that no water or humidity can ingress This avoids any bad or loose connections that w...

Page 3: ...roller plus and minus Follow the reverse procedure when uninstalling Additionally to avoid any voltage on the wires first connect the wire to the controller then to the battery photovoltaic modules Bu...

Page 4: ...controller 15A for ECO N Starting up the controller Self Test As soon as the controller is supplied with power either from the battery it starts a self test routine Then the display changes to normal...

Page 5: ...ed frequently at least weekly Otherwise the battery will permanently be damaged A battery can only be fully charged if not too much energy is drawn during the charging process Keep that in mind especi...

Page 6: ...sconnect short circuit of load Red LED blank Red LED flashing Low Voltage Disconnect Function The charge controller is equipped with a low voltage disconnection function to protect the battery against...

Page 7: ...ermanently damaged in case of short circuit 4 200 nominal current disconnect with 3s delay WARNING The combination of different error conditions may cause damage to the controller Always remove the fa...

Page 8: ...ttery wires fuses and battery Battery is empty after a short time Red LED on Battery shows low capacity Change battery No battery connected Green LED off No battery connected Connect batteries Battery...

Page 9: ...oltage protection 10 5 V Max PV panel voltage 30 V Max battery voltage 30 V Temperature compensation Charge voltage 4 2 mV K per cell Self consumption 5 mA Grounding Negative grounded Ambient temperat...

Page 10: ...19 ECO N SOA Safe Operating Area...

Page 11: ...acturer are neglected The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person unusual use wrong installation or bad system design Specifications...