CF CRIMPHANDY
30
PHOENIX CONTACT
105555_en_07
Attaching the service cover
•
Put on the service cover again when the device is switched off.
Initializing the crimping tool (Reset)
Initialize the device so that it travels to the initial position.
The device must be switched off.
•
Hold the reset button pressed with the service tool.
•
Press the ON button as well.
•
Release the ON button first.
•
Release the reset button.
•
The yellow indicator light lights up.
Removing the taped ferrule
•
Push the slide towards the front of the device.
•
Hold the slide in this position and remove the taped ferrule.
•
Always actuate the slide even if no tape was inserted.
Taking off the service cover
•
Take off the service cover. The crimping tool turns off automat-
ically.
Attaching the service cover
•
Put on the service cover again when the device is switched off.
A
B
NOTE:
No taped ferrules may remain in the device.