Mounting the Device
The device can be easily and quickly mounted from the rear of the device. A panel thickness
of 1 mm to 6 mm (0.039" to 0.236") is permitted for proper mounting.
1.
Cut the mounting cutout in the housing for the device size to be installed.
2.
Push the device through the mounting cutout from the front.
Figure 2-1
Mounting the device using a mounting bracket
3.
Fix the mounting brackets in the recesses provided (A).
4.
Pull the mounting brackets down until the snap into place (B).
5.
Secure the device using the threaded pins (C).
NOTICE: Damage
When installing the device, leave a gap of at least 30 mm (1.181") around the device to
ensure sufficient air circulation.
NOTICE: Damage
When the operating device is installed horizontally, please note that additional sources of
heat beneath the operating device may result in heat accumulation.
Make sure to allow sufficient heat dissipation!
Please observe the permissible temperature range specified in the technical data when
operating the device.
NOTICE: Damage
In order to ensure the degree of protection specified in the technical data, observe the fol-
lowing points:
–
A tolerance of ±0.5 mm is maintained for the mounting cutout.
–
The seal lies flat against the mounting surface.
–
The number of mounting brackets, given in the technical data, is used.
–
The threaded pins of the mounting brackets are tightened uniformly to a maximum
torque of 1 Nm.