TP 3XXXX/P
48
PHOENIX CONTACT
107460_en_00
4.1.1
Ethernet (X5)
A 10/100Base-T Ethernet interface is located at the operating device.
4.1.1.1
Pin Assignment
Connector in the operating device: RJ45 female connector.
4.1.1.2
Cable
4.1.1.3
Diagnostics
Ethernet diagnostics LEDs are located at the operating device.
Figure 4-2
Position of the ethernet diagnostics LEDs
Table 4-1
Assignment of the Ethernet interface
Pin
Designation
Function
1
Tx+
Transmitted Data, Positive Polarity
2
Tx-
Transmitted Data, Negative Polarity
3
Rx+
Received Data, Positive Polarity
4
n.c.
Not Connected
5
n.c.
Not Connected
6
Rx-
Received Data, Negative Polarity
7
n.c.
Not Connected
8
n.c.
Not Connected
NOTICE
Use a twisted pair cable of category 5 (CAT 5). The maximum cable length is 100 m
(328.084 feet).
See the IEEE 802.3 standard for further information.
Table 4-2
Ethernet diagnostics LEDs
LED
Color
State
Designation
Function
1
Green
On
ACT/LNK
Connected
Flashing
Sending / receiving ethernet
data telegram
2
Yellow
On
SPD 10/100
Operation in 100 MBit/s mode
Off
Operation in 10 MBit/s mode
or disconnected