PSR-...-24DC/ESD/5X1/1X2/300

102104_en_03

PHOENIX CONTACT

4

Switching capacity (360/h cycles)

4 A (24 V DC)
4 A (230 V AC)

Switching capacity (3600/h cycles)

2.5 A (24 V (DC13))
3 A (230 V (AC15))

Output fuse

6 A fast blow (undelayed)
10 A gL/gG NEOZED (delayed)

Output data

General data

Relay type

Electromechanically forcibly guided, dust-proof relay.

Nominal operating mode

100% operating factor

Degree of protection

IP20

Min. degree of protection of inst. location

IP54

Mounting position

any

Mounting type

DIN rail mounting

Air clearances and creepage distances between the power circuits

DIN EN 50178/VDE 0160

Rated insulation voltage

250 V

Rated surge voltage/insulation

4 kV / basic isolation, (safe isolation, reinforced insulation and 6 kV between the 
enabling current paths 

(13/14, 23/24, 33/34)

 and the remaining current paths 

and between 

13/14, 23/24, 33/34

 between each other.)

Pollution degree

2

Surge voltage category

III

Dimensions

Screw connection

Spring-cage connection

W x H x D

45 x 99 x 114.5 mm

45 x 112 x 114.5 mm

Connection data

Screw connection

Spring-cage connection

Conductor cross section, solid

0.2 mm² ... 2.5 mm²

0.2 mm² ... 1.5 mm²

Conductor cross section, stranded

0.2 mm² ... 2.5 mm²

0.2 mm² ... 1.5 mm²

Conductor cross section AWG/kcmil

24 ... 12

24 ... 16

Stripping length

7 mm

8 mm

Ambient conditions

Ambient temperature (operation)

-20 °C ... 55 °C

Ambient temperature (storage/transport)

-40 °C ... 70 °C

Max. permissible relative humidity (operation)

75 % (on average, 85% infrequently, non-condensing)

Max. permissible humidity (storage/transport)

75 % (on average, 85% infrequently, non-condensing)

Maximum altitude

̣

 2000 m (Above sea level)

Conformance / approvals

Approvals

ƚ ƒ »

Safety data

Stop category according to IEC 60204

0  , 1

Safety parameters for IEC 61508 - High demand

SIL

3

PFH

d

1.89 x 10

-9

Demand rate

< 12 Months

Proof test interval

240 Months

Duration of use

240 Months

Data only applies if the safety function is demanded at least once a year and the signal contact is read back.

The specifications apply assuming the following calculation basis

www.phoenixpowersupply.co.uk

Summary of Contents for 2981428

Page 1: ...ding to stop category 0 Two other enabling current paths drop out with a delay in compliance with stop category 1 The delay time is set in 24 increments via the rotary switch and the DIP switch in the upper housing part Features Emergency stop safety door and light grid monitoring Undelayed contacts suitable up to category 4 PL e EN ISO 13849 1 SILCL 3 EN 62061 Dropout delayed contacts suitable up...

Page 2: ...ting and indication elements 8 8 1 Connection assignment 8 9 Diagnostics 8 10 Function 9 11 Configuration 9 11 1 Setting the delay time 9 11 2 Protection against manipulation 9 12 Application examples 10 12 1 Single channel emergency stop monitoring 10 12 2 Two channel emergency stop monitoring 10 12 3 Two channel safety door monitoring 10 12 4 Light grid monitoring automatic start 10 www phoenixp...

Page 3: ... 1 Typical input current 155 mA DC Voltage at input start and feedback circuit approx 24 V DC Max permissible overall conductor resistance Input and reset circuit at UN 22 ǥ Input and start circuits at UN Typical response time 70 ms manual start 600 ms Auto start Typical release time 20 ms undelayed contacts Recovery time 1 s Output data Contact type 3 enabling current paths undelayed 2 enabling c...

Page 4: ...ns Screw connection Spring cage connection W x H x D 45 x 99 x 114 5 mm 45 x 112 x 114 5 mm Connection data Screw connection Spring cage connection Conductor cross section solid 0 2 mm 2 5 mm 0 2 mm 1 5 mm Conductor cross section stranded 0 2 mm 2 5 mm 0 2 mm 1 5 mm Conductor cross section AWG kcmil 24 12 24 16 Stripping length 7 mm 8 mm Ambient conditions Ambient temperature operation 20 C 55 C A...

Page 5: ...onths Duration of use 240 Months Safety characteristic data according to EN ISO 13849 Category 4 Undelayed contacts Performance level e for dropout delay contacts PL d CCF Passed Duration of use 240 Months Data only applies if the safety function is demanded at least once a year and the signal contact is read back The specifications apply assuming the following calculation basis B10d 230000 At 3 A...

Page 6: ...1 Y2 Feedback circuit S10 S11 S12 S21 S22 Input circuits S33 S34 S35 Start circuit 13 14 Undelayed enabling current paths 23 24 33 34 41 42 Signaling current path 57 58 Delayed enabling current paths 67 68 A1 Y1 Y2 S10S11 S12 13 23 33 41 57 K1 K2 K3 K4 Logic A2 S33S34 S35 S21 S22 14 24 34 42 58 68 67 T A C I A TH 2 2 10 20 30 40 0 10 20 30 40 50 60 0 45 55 50 60 70 80 55 www phoenixpowersupply co ...

Page 7: ...WARNING Danger due to faulty devices The devices may be damaged following an er ror and correct operation can no longer be en sured In the event of an error replace the device im mediately Repairs to the device especially if the hous ing must be opened may only be carried out by the manufacturer or authorized persons Otherwise the warranty is invalidated NOTE Risk of damage to equipment due to inc...

Page 8: ... 3 5 3 3 3 4 2 3 2 4 1 3 1 4 P S R E S D 3 0 0 A 1 S 2 1 S 2 2 A 2 S 1 0 S 1 1 S 1 1 S 1 2 Y 1 Y 2 5 8 6 8 4 2 5 7 6 7 4 1 P o w e r K 1 K 2 K 3 t K 4 t 1 2 T i m e B A o n 1 6 3 4 5 2 A 2 APPROVALS 13 23 33 41 57 58 14 24 34 42 58 68 1 2 3 4 5 6 0 2 0 4 0 8 1 6 2 4 3 2 4 4 8 6 4 12 8 19 2 50 100 150 200 250 300 0 6 0 8 1 1 2 25 32 38 on 1 2 3 4 5 6 7 8 15 14 13 9 10 12 11 Designation Explanation ...

Page 9: ...ch and the DIP switch in the upper housing part 1 Set a time period using the DIP switches 2 Set the desired delay time with the rotary switch Figure 4 Configuring the time delay 11 2 Protection against manipulation Once the time has been set the rotary switch and the DIP switch can be protected against manipulation by covering with the label provided Figure 5 Applying the label Once configuration...

Page 10: ...al monitored start 12 4 Light grid monitoring automatic start Automatic start Monitoring of external contactors Suitable up to category 4 PL e EN ISO 13849 1 SILCL 3 EN 62061 Figure 9 Light grid monitoring automatic start For an automatic start bridge contacts S33 and S35 as well as Y1 and Y2 K3 K4 Y Y 2 1 S1 M N L1 L K3 K4 A1 23 33 13 41 A2 S33 S34 S35 24 34 14 42 PSR ESD 5x1 1x2 S S S 12 11 10 S...