22
5756B
4. To integrate the controller board, select the "FM-300"
subdirectory and then the "FM 353 for Step Motor"
module. Link the module to your project.
Figure 20
Selecting the FM 353 for Step Motor module
The IBS S7 300 DSC-T controller board is emulated as
S7 FM-POS (FM 353 for Step Motor) in the analog area with
16 byte inputs/outputs.
5. In the "Hardware Configuration" window, double-click with
the left mouse button on the "FM 353 for Step Motor" item.
This opens the "Properties - FM 353 Step ..." dialog box
(Figure 21).
6. Click on the "Properties... Addresses" tab (Figure 21).
This displays the base address of the controller board
specified by the slot.
Enter this address in IBS CMD. The procedure for this
is described in the Section "Startup With
IBS CMD SWT G4 Configuration Software" on
page 27.