RAD-ISM-900-EN-BD…
5-12
PHOENIX CONTACT
2476_en_I
Table 5-2
Modbus Pulse Memory Map
00xxx
40xxx
17
Module #1 Input 1 Value Control Bit
Module #1 Input 1 LSW Value
18
Module #1 Input 2 Value Control Bit
Module #1 Input 1 MSW Value (Pulse mode only)
19
Module #1 Input 1 LSW Value Store (Pulse mode only)
20
Module #1 Input 1 MSW Value Store (Pulse mode only)
21
Module #1 Input 2 LSW Value
22
Module #1 Input 2 MSW Value (Pulse mode only)
23
Module #1 Input 2 LSW Value Store (Pulse mode only)
24
Module #1 Input 2 MSW Value Store (Pulse mode only)
25
Module #1 Output 1 LSW Value
26
Module #1 Output 1 MSW Value (Pulse mode only)
27
Module #1 Output 1 Absolute or Differential Operation LSW
28
Module #1 Output 1 Absolute or Differential Operation MSW
29
Module #1 Output 2 LSW Value
30
Module #1 Output 2 MSW Value (Pulse mode only)
31
Module #1 Output 2 Absolute or Differential Operation LSW
32
Module #1 Output 2 Absolute or Differential Operation MSW
33
Module #2 Input 1 Value Control Bit
Module #2 Input 1 LSW Value
34
Module #2 Input 2 Value Control Bit
Module #2 Input 1 MSW Value (Pulse mode only)
35
Module #2 Input 1 LSW Value Store (Pulse mode only)
36
Module #2 Input 1 MSW Value Store (Pulse mode only)
37
Module #2 Input 2 LSW Value
38
Module #2 Input 2 MSW Value (Pulse mode only)
39
Module #2 Input 2 LSW Value Store (Pulse mode only)
40
Module #2 Input 2 MSW Value Store (Pulse mode only)
41
Module #2 Output 1 LSW Value
42
Module #2 Output 1 MSW Value (Pulse mode only)
43
Module #2 Output 1 Absolute or Differential Operation LSW
44
Module #2 Output 1 Absolute or Differential Operation MSW
45
Module #2 Output 2 LSW Value
46
Module #2 Output 2 MSW Value (Pulse mode only)
47
Module #2 Output 2 Absolute or Differential Operation LSW
48
Module #2 Output 2 Absolute or Differential Operation MSW
49
Module #3 Input 1 Value Control Bit
Module #3 Input 1 LSW Value
50
Module #3 Input 2 Value Control Bit
Module #3 Input 1 MSW Value (Pulse mode only)
51
Module #3 Input 1 LSW Value Store (Pulse mode only)
52
Module #3 Input 1 MSW Value Store (Pulse mode only)
53
Module #3 Input 2 LSW Value
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-12970-Phoenix-Contact-2900016-Radio-900-MHz-Ethernet-Radio.aspx