PHOENIX CONTACT page 4  of  9

1

1

1

1

 

DC input, unbuffered  

 24 V DC input voltage  
 (0.5 mm

2

 to 16 mm

2

 solid)  

 (0.5 mm

2

 to 10 mm

2

 stranded)  

 (20 - 6 AWG)  
 Internal fuse 50 AT

2

2

2

2

 

DC output, buffered

 24 V DC output voltage  
 (0.5 mm

2

 to 16 mm

2

 solid)  

 (0.5 mm

2

 to 10 mm

2

 stranded) (20 - 6 AWG)

 The device is idling-proof and short-circuit-proof.

3

3

3

3

 24 V battery module connection

4

4

4

4

 

Floating PDT (11,12,13): Alarm

5

5

5

5

 

Floating PDT (21,22,23): Battery Mode

6

6

6

6

 

Floating PDT (31,32,33): Battery Charge

7

7

7

7

 

24 V supply voltage, maximum current limit 0.2 A  

    for grouped contacts

 

11, 21, 31

8

8

8

8

 

Remote shutdown (R1, R2)

9

9

9

9

 

Universal DIN rail adapter UTA 107

0

0

0

0

 

Red LED: Alarm

!

!

!

!

 

Yellow LED: Battery Mode/Battery

 

Charge

"

 

Green LED: Power In OK

§

§

§

§

 Buffer time setting 0.5 - 30 minutes

$

$

$

$

 

Battery module/Service setting selection

Uninterruptible Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40

3. Device View, Connections, and Control Elements

4. Safety Notes and Warning 
Instructions

To ensure that the device can be operated safely 

and all functions can be used, please read these 
instructions carefully.

The QUINT-DC-UPS is a built-in device. 

Installation 

and startup

 must only be carried out by quali

fi

ed 

personnel. The relevant country-speci

fi

c regulations 

(e.g., VDE, DIN) must also be observed.

Before startup it is particularly important to ensure 

that:
•  All supply lines have suf

fi

cient fuse protection and 

are the correct size.

•  All output cables are the correct size for the maximum 

device output current or have separate fuse 
protection.

•  Suf

fi

cient convection is ensured.

• The fuse on the battery module is always removed 

when carrying out any work.

Figure 04

+     

 –

DC 24 

V   40 

A

Input       Output

3  14

DC

OK

+  +  

13  14

DC

OK

+  +

13  14

DC

OK

+  + 

+     

 –

+24V 0,2A

11

   21

12   13  2

11
Alarm

Bat.-Mode
Bat.-Charge

QUINT

-DC-UPS/24DC/40

Order-No.: 28 66 24 2
Input:
Operational V

oltage:

Output:

24VDC/43A
22.5-30VDC
24VDC/40A

APPROV

ALS

Read installation instructions
before connecting

- 25 … + 

  

70 

°

C

- 13 … + 158 

°

F

EN 61000-6-2
EN 50081-1

www

.interface.phoenixcontact.com

U

INDUSTRIAL
CONTROL
EQUIPMENT
43KA

LISTED

–2

5

F

Alarm

Power In OK

QUINT DC-UPS 40 

A

Bat.-Mode

Bat.-Charge

Batter

y

3   1

4 DC

OK

+  +  –

Alarm

Power In

OK

+      –

31  R1  R2

2  23  32  33

21
 Bat.-
Mode

31
 Bat.-
Charge

R1     R2
Remote

OFF

ON

10

15

5

3

2

1

0,5

20

30

t

max

[min]

Service

3,4

12

7,2

Bat.-Select

[Ah]

7

7

7

7

5

5

5

5

4

4

4

4

1

1

1

1

2

2

2

2

3

3

3

3

6

6

6

6

8

8

8

8

9

9

9

9

$

$

$

$

§

§

§

§

"

"

"

"

!

!

!

!

0

0

0

0

Summary of Contents for QUINT-DC-UPS/24DC/40

Page 1: ...g is thus required for maximum system availability Three floating PDT contacts and three LEDs are provided for function monitoring which indicate all the operating states clearly So that relay signali...

Page 2: ...harge current Battery presence check time interval Battery quality test time interval Memory Medium Nominal voltage Nominal capacity Charge current QUINT DC UPS 24DC 40 DC UPS Module U u F Type Order...

Page 3: ...cations Signaling Power In OK Alarm Battery Mode Battery Charge Approvals Standards Electrical equipment of machines Electrical safety of IT equipment Industrial control equipment Shipbuilding Electro...

Page 4: ...ully The QUINT DC UPS is a built in device Installation and startup must only be carried out by qualified personnel The relevant country specific regulations e g VDE DIN must also be observed Before s...

Page 5: ...4 DC OK 24V 0 2A 11 21 12 13 2 11 Alarm Bat M ode Bat C harg e QUIN T D C U PS 24DC 20 Ord er No 28 66 23 9 Input Opera tional Voltage Output 24VDC 22A 22 5 3 0VDC 24VDC 20A APPROVALS Read in sta llat...

Page 6: ...onnected For reliable and safe to touch connections Strip 10 mm 0 39 in from the input and output side connector ends and 7 mm 0 28 in from the signal connector ends To maintain UL approvals use coppe...

Page 7: ...24DC type battery modules The following battery modules are recommended QUINT BAT 24DC 3 4AH Order No 2866349 QUINT BAT 24DC 7 2AH Order No 2866352 QUINT BAT 24DC 12AH Order No 2866365 When using QUIN...

Page 8: ...ce remains off until remote shutdown is deactivated Connected loads are supplied as long as the supply voltage is present 6 Setting Options on the Device Fig 13 6 1 Buffer Time Setting Buffer mode can...

Page 9: ...idling proof 7 2 Signaling Three floating PDT contacts and three indicators are provided for function monitoring xx xx Contact closed 1x Alarm 2x Battery Mode 3x Battery Charge x1 group contact x2 N C...