background image

 

QUINT POWER provides:

 

•  

 

Preventive function monitoring

 

 through 

professional signaling

•  

 

Global use

 

 due to a wide range input

•  

 

A high level of operational safety

 

 even in complex 

global networks

•  

 

Reliable startup of heavy loads 

 

due to POWER 

BOOST

The reliability of a power supply determines the 

availability of individual components in a system and 
whether complex systems can function safely. 

The globalization of markets increases the demands 

placed on the power supply. A wide range input and a 
high level of availability are required.

These requirements are met by Generation 2 

QUINT POWER.

 

1. Short Description

 

The QUINT POWER product range offers universal 

DC power supplies from 60 - 960 W. Depending on the 
type, regulated and adjustable output voltages of 
12 V DC, 24 V DC or 48 V DC are available for output 
currents of 2.5 A, 5 A, 10 A, 20 A, 30 A, and 40 A.

These devices, which are designed as primary 

switched-mode regulators, operate with a high level of 
ef

fi

ciency so that the heat loss is kept to a minimum.

The high level of operational safety is also ensured in 

complex global networks. QUINT POWER also 
operates in applications where static voltage dips, 
transient power supply failures or phase failure are 
common.

Large capacitors ensure mains buffering of more 

than 20 ms at full load. All 3-phase QUINT POWER 
units provide the complete output power even in the 
event of a continuous phase failure.

Reliable startup of heavy loads is ensured by a 

power reserve of up to 50% - the POWER BOOST.

Preventive function monitoring diagnoses an 

impermissible operating state and minimizes 
downtimes in your system. An active transistor output 
and an electrically isolated relay contact are provided 
for remote monitoring of this state.

This signal not only provides information on the 

device function, but also indicates a system overload at 
an early stage.

 

2. Area of Application

 

QUINT POWER can be used globally due to the 

consistent provision of a wide range input. 

In this way, your entire system can be tested at any 

production location in the world and can be delivered to 
any location in the world without faulty switching of the 
input voltage. This reduces storage costs and logistical 
effort.

An international approval package including CB 

Scheme, UL 60950 for IT equipment, and UL 508 for 
industrial control equipment enables the device to be 
used globally.

Safe operation in adverse conditions is emphasized 

by the approval of all QUINT POWER units with 24 V 
output voltage by Germanischer Lloyd.

 

Power Supply, Primary Switch Mode
for Universal Use
QUINT-PS-100-240AC/12DC/10

 

Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany

Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com

Local Contact: www.phoenixcontact.com/salesnetwork

Summary of Contents for QUINT-PS-100-240AC/12DC/10

Page 1: ...ad All 3 phase QUINT POWER units provide the complete output power even in the event of a continuous phase failure Reliable startup of heavy loads is ensured by a power reserve of up to 50 the POWER B...

Page 2: ...iciency Response time UOUT 10 90 Residual ripple switching peaks 20 MHz Can be connected in parallel Internal surge voltage protection Signal Output Data DC OK active 3 Uout 0 9 x UN high signal DC OK...

Page 3: ...Criterion A Normal operating characteristics within the specified limits 3 Criterion B Temporary adverse effects on the operating characteristics that the device corrects independently 4 kV AC type t...

Page 4: ...L N 5 QUINT POWER 13 14 DC OK C 12V 10A DC 13 14 DC OK O utput DC 1 DC O K 13 14 Figure 04 7 2 1 3 4 5 6 Power Supply Primary Switch Mode for Universal Use QUINT 12 V DC 10 A 4 Device View Connections...

Page 5: ...0022 35 and should be mounted horizontally input terminal blocks facing downwards Installation Dimensions To ensure sufficient convection we recommend a minimum spacing of 5 cm 1 969 in to other modul...

Page 6: ...DIN rail and then snap it downwards Removal Release the snap on catch using a screwdriver and then detach the module from the bottom edge of the DIN rail 6 3 Flat Mounting Position A flat mounting pos...

Page 7: ...f To maintain UL approvals use copper cables which are designed for operating temperatures of 75 C 167 F The following cable cross sections can be connected To maintain EN 60950 UL60950 flexible cable...

Page 8: ...cation Electrically Isolated Contact Figure 12 When opened the electrically isolated signal contact indicates that the output voltage has fallen more than 10 below the set value Signals and ohmic load...

Page 9: ...is reduced until the short circuit on the secondary side is removed The U I characteristic curve ensures that both heavy capacitive loads and devices with DC DC converters can be supplied by QUINT POW...

Page 10: ...h place particularly high requirements on operational safety If a fault occurs in the primary circuit of device 1 device 2 automatically takes over the complete power supply without interruption and v...

Reviews: