UM EN OPC 7015/OPC 7022
8155_en_00 PHOENIX
CONTACT
6.4
N
ETWORK CONNECTION
(RJ45)
If the drivers required for functioning are installed on the device, the control system may
be integrated in an Ethernet network supporting the 10/100 Mbit standard by using the
Ethernet 10/100BaseT network connector. Specifications of this network topology must be
observed in this case. You can install the drivers required for the network function from
the enclosed service CD, should they not be installed on the device.
PIN NUMBER
SIGNAL NAME
1
TX +
2
TX -
3
RX +
4
NC
5
NC
6
RX -
7
NC
8
NC
Pos: 30 /Datentechnik/Schnittstellen/Serielle Schnittstelle COM RS232/Serielle Schnittstelle COM (RS232) für OPC / IPC / CPC / PLC / OTC / ITC / VMT / MSA-Serie @ 1\mod_1249303286408_6.doc @ 6104 @
6.5
S
ERIAL
COM
INTERFACE
(RS232)
The serial interface is also used for digital data transmission. The RS232 interface can be
connected by using a commercially available 9-pin SUB-D cable.
PIN NUMBER
SIGNAL NAME
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Note:
This interface is not electrically isolated.