www.hartmann-electronic.com
Rev. 1.2
22
6. Specification
Electrical
AC Input
Operating Voltage Range
90 VAC to 264 VAC
Operating frequency Range
47 Hz - 63 Hz
Input Current
6 A
Efficiency
>86% @ full load
DC Output
Short Circuit protection on all outputs.
Over Voltage protection on +5 V, +12 V, +3.3 V.
Power Supply
Main Power:
EFORE, RCB600-AABB
Power available for Backplane
Table 6-2 shows the available Power over the specified operating temperature Range
Voltage
Maximum Current
Maximum Power
+5V AUX
2 A
10 W
+5V
9 A
45 W
+3.3V
14 A
45 W
+12V
12 A
135 W
-12V
2 A
25 W
As shown in Table 6-2 The Backplane can deliver 260 W of total power to the Modules, over the specified
temperature range.
The power consumption of all PXIe modules that are installed into the chassis must not exceed the limits in table
6-2.