Rev. 1.3
12
https://www.hartmann-electronic.com/
3.4
Electrical Connection and Power Supply
3.4.1
Power Entry Module
The power input module is provided with an IEC 320-C14 connector, integrated Filter,
fuseholder 1-pole and Line Switch 2-pole.
Technical Data
Ratings IEC
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA
1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz
Leakage Current
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 μA (250 V / 60 Hz)
Dielectric Strength
>1.7 kVDC between L-N
>2.7 kVDC between L/N-PE
Test voltage (1 min/50 Hz)
Allowable Operation Temp
-25 °C to 85 °C
Climatic Category
25/085/21 acc. to IEC 60068-1
Degree of Protection
from front side IP 40 acc. to IEC 60529
Protection Class
Suitable for appliances with protection class 1 acc. to IEC
61140
Terminal
Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s
Screw-on mounting, max 8 mm
Material Housing
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1 UL 498, CSA C22.2 no. 42 (for
cold conditions) pin-temperature 70 °C, 10 A, Protection
Class 1
Fuseholder
1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Rated Power Acceptance @ Ta 23 °C
5 x 20 2 W (1 pole)/ 1.6 W (2-pole) per pole
Power Acceptance @ Ta > 23°C
Admissible power acceptance at higher ambient
temperature see derating curves
Line Switch
Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-
1
Line Filter
Standard and Medical Version, IEC 60939, IEC 60601
‑
1,
UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8
MTBF
> 2'000'000 h acc. to MIL-HB-217 F
Figure 3-14 Power Entry Module