https://www.hartmann-electronic.com/
15
Rev. 1.3
Circuit Topology
Forward circuit.
Transient Response
Peak transient less than 100mV and recovers within 2mS after
25% load-change.
Safety Standard
IEC 60950-1 Class I.
Construction
Eurocard 3U X 8HP X 160mm CompactPCI format
Operating Temperature
0 to +50 °C at full load with specified air flow. Derates linearly to
50% at +70 °C.
Storage Temperature
-40 to +85 °C.
Temperature Coefficient
Typ. ±0.02% / °C.
Cooling
At least 20 CFM(600 LFM) moving air is required to achieve full
rating power 250W in a confined area.
Power Density:
4.58 Watts/ Cubic Inch.
Output Current
+5V
+3.3V
+12V
-12V
Min
Typ.
Max. Min.
Typ.
Max. Min. Typ. Max. Pk Min. Typ. Max.
Pk.
0A
25.0A 33.0A
0A
18.0A 33.0A
0A
5.0A 5.5A
6A
0A
0.5A
1A
1.5A
Figure 3-16 AC Power Supply 3U, 250W