https://www.hartmann-electronic.com/
17
Rev. 1.3
3.5.2
Fans
VME64x Basic Systems with build-in fans
In the VME64x Basic Systems with build-in fans, the speed will be controlled by an external
thermistor.
VME64x Basic 1 U 84 HP Depth 283 mm
LMH0000200
VME64x Basic 2 U 84 HP Depth 283 mm
LMH0000170
VME64x Basic 4 U 84 HP Depth 283 mm
LMH0000180
VME64x Basic Systems with Fan Tray
In the VME64x Basic Systems with hot-swap fan trays, the speed will be controlled by an
external thermistor, and a lock sensor gives alarm if a fan speed goes down or a fan is
blocked.
VME64x Basic 1 U 84 HP Depth 283 mm with fan tray *
LMH0000312
VME64x Basic 2 U 84 HP Depth 283 mm with fan tray
LMH0000240
VME64x Basic 4 U 84 HP Depth 283 mm with fan tray
LMH0000260
*) 40 x 40 x 28 mm fans are without speed control. Different fans can be installed in the fan
try.
Technical data DC fan 40 x 40 x 28 mm (LMH0000200)
Dimensions:
40mm x 40mm, 28mm thick
Rated Voltage:
12V
Rated Current
0.195A
Rated Input:
2.34W
Rated Speed:
8700rpm
Air Flow:
11.3 cfm (0.32 m³/min)
Static Pressure:
103Pa (0.414 inchH
2
O)
Noise:
37dB(A)
Operating Temperature
-10°C - +60°C (Non-condensing)
Storage Temperature
-30ºC to +70ºC
Life Expectancy
40.000h
Technical data DC fan 40 x 40 x 28 mm (LMH0000312 with removable fan try)
Different fans can be installed in the fan try.
1.
Dimensions:
40mm x 40mm, 28mm thick
Rated Voltage:
7V to 12V
Rated Current
0.28A
Rated Input:
3.36W
Rated Speed:
10300rpm
Air Flow:
13.4 cfm (0.38 m³/min)
Static Pressure:
143Pa (0.574 inchH
2
O)
Noise:
40dB(A)
Operating Temperature
-20°C - +60°C (Non-condensing)
Storage Temperature
-30ºC to +70ºC
Life Expectancy
40.000h