Rev. 1.3
4
https://www.hartmann-electronic.com/
Shelf ambient temperature may not exceed 40°C.
2.4.7
Mounting Considerations
During the course of handling, shipping, and assembly, parts could become loose or
damaged.
Do not operate a shelf in this condition, as this may cause damage to other equipment.
2.4.8
Electrical Hazards
The caution label on the system's rear near the grounding studs shows that you have
to create an earth connection because there may be a high leakage current which is
considered hazardous.
High leakage current can cause injuries.
Ensure that the system is properly grounded at all times, the following conditions shall be
met:
•
This equipment shall be connected directly to the AC supply system earthing
2.4.9
Board Installation
Electrostatic discharge and incorrect board installation or removal can damage circuits or
shorten their life.
•
Before touching the boards, rear transition module or electronic components, make
sure that you are working in an ESD-safe environment
•
Boards should be inserted and removed using their handles, do not force the board by
applying pressure to the front panel.