Figure 8: Clockwise feet locations
the unit against the wall, the restoration professional will
place the 50Hz Axial air mover at 4.5° due to the housing’s
built-in design. Industry experts agree placing 50Hz Axial Air
Movers 45° angle to the wall wastes air flow and reduces the
performance by forcing air up the wall.
The best set up angle for quickly and completely drying the
sill plate is 4.5°. Set-up angles greater than 4.5° may be
used under unique circumstances such as corner air flow and
structure variations. Set-up angle should never exceed 23°.
Figure 5: 4.5° to wall
as shown
Figure 6: Placement for counter-clockwise drying
Figure 7: Birds eye view of room set-up
Counter
clockwise
airflow
pattern
Clockwise
airflow
pattern
Making use of factory installed feet (4)
Making use of user installed feet (2)
User installed feet
for use during
clockwise drying
set-ups
Factory installed feet for use
during counter clockwise drying
6.3 Orienting of Directional Drying System
The 50Hz Axial air mover dries in counter-clockwise and
clockwise directions for optimum ease of use. The 50Hz Axial
air mover ships with rubber feet on one side of the unit for
counter-clockwise drying.
When the water restoration professional needs to employ
clockwise drying (such as the need to dry a door jamb),
simply rotate the 50Hz Axial air mover 90° so the FOCUS
Technology corner points toward the door jamb and floor for
the clockwise drying.
If the water restoration professional dries in the clockwise
direction often, we suggest attaching the two (factory
provided) rubber feet into the threaded holes on the side
of the unit. By attaching the rubber feet and creating the
optimal downward angle of 4.5°, the Phoenix 50Hz Axial
Air Mover will maximize air velocity across the floor and wall
when drying in the clockwise direction.
Figure 4: Airflow of the Phoenix 50Hz Axial Air Mover mea-
sured 3.5” parallel to wall.
2500
2000
1500
1000
500
0
0 Feet 5 10 15 20 25
Air V
elocity (fpm)
Immediate high velocity air flow at
the outlet of the fan.
7 Operating Instructions
The Phoenix 50Hz Axial Air Mover as packaged is ready to be
put into service after attaching the appropriate plug/cord set.
Inspect the unit completely for any shipping damage. Place
the unit on the ground. Orient the unit so the desired air flow
direction is the same as the arrow indicator sticker in the
FOCUS Technology corner on the interior of the unit. Plug the
unit into a grounded outlet and select the drying mode shown
in Figure 9.