Figure 8: Clockwise feet locations

the unit against the wall, the restoration professional will 

place the 50Hz Axial air mover at 4.5° due to the housing’s 

built-in design. Industry experts agree placing 50Hz Axial Air 

Movers 45° angle to the wall wastes air flow and reduces the 

performance by forcing air up the wall.
The best set up angle for quickly and completely drying the 

sill plate is 4.5°. Set-up angles greater than 4.5° may be 

used under unique circumstances such as corner air flow and 

structure variations. Set-up angle should never exceed 23°.

Figure 5: 4.5° to wall 

as shown

Figure 6: Placement for counter-clockwise drying

Figure 7: Birds eye view of room set-up

Counter 

clockwise 

airflow 

pattern

Clockwise 

airflow 

pattern

Making use of factory installed feet (4)

Making use of user installed feet (2)

User installed feet 

for use during 

clockwise drying 

set-ups

Factory installed feet for use 

during counter clockwise drying

6.3 Orienting of Directional Drying System

The 50Hz Axial air mover dries in counter-clockwise and 

clockwise directions for optimum ease of use. The 50Hz Axial 

air mover ships with rubber feet on one side of the unit for 

counter-clockwise drying.
When the water restoration professional needs to employ 

clockwise drying (such as the need to dry a door jamb), 

simply rotate the 50Hz Axial air mover 90° so the FOCUS 

Technology corner points toward the door jamb and floor for 

the clockwise drying.
If the water restoration professional dries in the clockwise 

direction often, we suggest attaching the two (factory 

provided) rubber feet into the threaded holes on the side 

of the unit. By attaching the rubber feet and creating the 

optimal downward angle of 4.5°, the Phoenix 50Hz Axial 

Air Mover will maximize air velocity across the floor and wall 

when drying in the clockwise direction.

Figure 4: Airflow of the Phoenix 50Hz Axial Air Mover mea-

sured 3.5” parallel to wall.

2500

2000

1500

1000

500

0

0 Feet               5                    10                     15                   20                     25

Air V

elocity (fpm)

Immediate high velocity air flow at 

the outlet of the fan.

7 Operating Instructions

The Phoenix 50Hz Axial Air Mover as packaged is ready to be 

put into service after attaching the appropriate plug/cord set. 

Inspect the unit completely for any shipping damage. Place 

the unit on the ground. Orient the unit so the desired air flow 

direction is the same as the arrow indicator sticker in the 

FOCUS Technology corner on the interior of the unit. Plug the 

unit into a grounded outlet and select the drying mode shown 

in Figure 9.

Summary of Contents for 4030940

Page 1: ...ure designed to fit existing vehicle rigging superior cord management and hour meter Conventional 50Hz Axial air movers create a circular air jet With a circular air jet the only way to get air into the square corner is to point the fan towards the corner This angle toward the wall wastes valuable air velocity and throw distance FOCUSTM Technology creates an air jet with a square corner resulting ...

Page 2: ...se murale ou la prise d alimentation électrique Toujours utiliser une prise mise à la terre Ne jamais utiliser l équipement électrique dans de l eau stagnante Ne jamais utiliser sans les grilles de protection Des blessures risquent d en résulter Ne pas passer les doigts ou d autres objets dans les grilles de protection Ne pas diminuer le débit d air arrivant jusqu à l appareil L appareil risque de...

Page 3: ...ropriate grounded earthed outlet 5 2 Integrated Cord Wrap The Phoenix 50Hz Axial Air Mover features integrated cord management Wrap the cord around the cord wrap as shown and tuck under the previous wrap 6 Applications 6 1 Sizing for Water Restoration Jobs Current industry standards call for one air mover per 3 5 meters 10 16 linear feet of wall space dependent upon the Class of water damage For c...

Page 4: ...r ships with rubber feet on one side of the unit for counter clockwise drying When the water restoration professional needs to employ clockwise drying such as the need to dry a door jamb simply rotate the 50Hz Axial air mover 90 so the FOCUS Technology corner points toward the door jamb and floor for the clockwise drying If the water restoration professional dries in the clockwise direction often ...

Page 5: ...position drying selector switch in the OFF position or the connected standard AC wall outlet power has been turned off 8 3 3 Position Drying Selector Switch The 3 position drying mode selector switch This switch is used to select the Phoenix 50Hz Axial Air Mover s mode of operation The 3 modes of operation are OFF LOW or HIGH 9 Maintenance WARNING Disconnect the unit from power before servicing or...

Page 6: ...ED PLUG M CAPACITOR BLK BLK left hand pole right hand pole GRY 230 VAC 50 hz Note Switch is Double Pole Double Throw GRY YEL 10 Replacement Parts and Optional Accessories Contact the factory at 1 800 533 7533 or 1 608 237 8400 to order replacement parts or optional accessories 4029721 Switch Rocker On Off On 4025320 Grill Safety Intake 4025321 Grill Safety Exhaust 4025460 Axial Air Mover Stand 402...

Page 7: ...on freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Phoenix 50Hz Axial Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix 50Hz Axi...

Reviews: