PAGE # 13
Call 1-877-744-3649 for assistance or visit us at www.phoenixinno.com
LP GAS CYLINDER
(FOR LP MODELS ONLY)
16.
Always use the pressure regulator and hose assembly provided with the appliance to connect to a LP gas cylinder.
Never connect to an unregulated LP gas supply. Contact our customer service department for replacement parts at
1-877-744-3649 or www.phoenixinno.com.
17.
When connecting the LP gas cylinder to the appliance, always test for gas leaks.
See “Leak Test” section of this manual.
18.
If you smell gas, do not use the appliance until the source of the leak has been
detected and repaired .
19.
Always shut off the LP gas cylinder service valve as well as the burner control valves
when the appliance is not in use.
20.
Be sure the LP gas cylinder service valve and burner control valve(s) are “OFF”.
21.
Set a full LP gas cylinder into the well located on the bottom of the appliance and secure in place.
22.
Center the probe of the appliance side connection in the cylinder service valve outlet and hold in place.
With your other hand, turn the plastic nut clockwise until fully engaged on the cylinder service valve
ACME
thread.
(See Fig. 13)
DO NOT USE TOOLS. HAND TIGHTEN ONLY.
23.
Perform the leak test (see “Leak Test” section of this manual) on all connections.
24.
When lighting the grill, follow the lighting instructions as stated in this manual.
Always open the LP gas cylinder service valve before opening the burner control valve(s)
to avoid activating the flow limiting device. See “Hose and Regulator Assembly” section
of this manual for more details of the flow limiting device.
HOSE & REGULATOR ASSEMBLY
(FOR LP MODELS ONLY)
1.
All models come equipped with a standard LP gas hose and regulator including the
appliance side connection for a CGA No 791 Cylinder Connection Device .
a. The CGA No 791 connection incorporates a magnetic flow limiting device that
acts to limit the flow of gas if a leak is detected between the regulator and
the burner valve(s).
b. If the burner valve(s) is open prior to the LP gas cylinder service valve being
opened, the connection will interpret this free flow of gas to be a leak.
c. The connections safety feature will reduce gas flow from the regulator to
the appliance to a minimal level.
d. Be sure that all burner valves are closed prior to opening the LP gas cylinder
service valve to ensure that the connection flow limiting device is not triggered mistakenly.
e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder
service valve and the burner valves, wait 10 seconds to allow the device to reset, open the cylinder service valve,
then open the burner valves and light the grill as per lighting instructions.
2.
Be sure to protect the hose from dripping grease and any hot surfaces – including the base of the appliance.
Serious danger may result if the hose contacts any hot surface.
3.
Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the appliance. If the hose shows signs of cracks, abrasions,
cuts or damage of any kind, do not operate the appliance. Fix or replace the hose as required before using the appliance.
For assistance with repair or replacement of the hose, call our customer service line at
1-877-744-3649 or www.phoenixinno.com. Use only replacement parts from Phoenix Innovations Corp.
b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the cylinder or at least
once per year. If there is any indication of damage, have the seal replaced by a certified gas dealer before operating the appliance.
4.
Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve – hand tighten only.
5.
Be sure not to cross thread the connection when tightening the CGA No 791 connection on to the LP gas cylinder service valve.
6.
Always perform the “leak test” (see leak test section) after attaching the connection to the LP gas cylinder service valve.
O
P
E
R
A
T
I
O
N
C
O
N
N
E
C
T
I
O
N
Cylinder
Hand Wheel
Cylinder
Service Valve
Straight
Fig. 13
For Models:
PH603SB
PH603SBN
Regulator
Nipple has to be centered
into the LP cylinder service valve.
Fig. 14
Hose
Regulator
Fig. 12
✓
✓