2
www.UsePhoenix.com • sales@UsePhoenix.com
Toll-Free 1-800-533-7533
Table of Contents
Introduction
............................................................................1
1. Safety Certifications
.......................................................2
2. Specifications
.................................................................2
3. Operation
........................................................................2
3.1 Transporting ..............................................................2
3.2 Electrical Requirements ...........................................3
3.3 Condensate Removal ...............................................3
3.4 Ducting ......................................................................3
3.5 Defrost Cycle .............................................................3
3.6 Power Button ............................................................3
3.7 Purge Button .............................................................3
3.8 Hour Meter ................................................................3
3.9 Hours Button ............................................................3
3.10 Defrost Light ...........................................................3
3.11 Bypass Control ........................................................3
4. Maintenance
...................................................................4
4.1 Air Filter .....................................................................4
4.2 Storage ......................................................................4
5. Service
.............................................................................4
5.1 Technical Description ...............................................4
5.2 Troubleshooting ........................................................5
5.3 Air Mover ...................................................................6
5.4 Thermistor .................................................................6
5.5 Condensate Pump ....................................................6
5.6 Float Safety Switch ...................................................6
6. Options & Accessories
...................................................6
7. Wiring Diagram
..............................................................7
8. Service Parts
...................................................................8
9. Warranty
..........................................................................9
1 Safety Certifications
The Phoenix R175 conforms to standards ANSI/UL 474 and
CSA C22.2 No.92.
2 Specifications
Part No.
4029200
Power
6.3 amps, 110-120 VAC, Grounded
Water
92 pints/day @ AHAM (80°F, 60%)
Removal
21 gal/day maximum @ saturation
Blower
230 CFM without external ducting
210 CFM @ .15 IWG external static
Refrigerant
1 lb, 8 oz. R410a
Charge
Operating
33°F to 110°F
Range
Filter
12” x 12” x 1” Pleated Media MERV-8
Duct
Intake – 12” Flex-Duct
Options
Supply – 10” Lay-Flat
Warranty
Five years;
1st year 100% of Parts and Labor
2nd-5th year 100% of Parts of sealed
refrigeration system.
Size
33” high x 20” wide x 20” deep
Weight
105 lbs
Patent
7,246,503
7,281,389
7,540,166
3 Operation
Place dehumidifier inside structure, place
condensate hose into a drain, or a very
large container, and turn on. To decrease
drying times, make sure all windows and
doors are closed to the outside and seal
off the wet area from any unaffected
areas.
3.1 Transporting
The Phoenix R175 features a high-impact
roto-molded housing which protects the unit airways, and
while loading into vehicles. The unit was designed to make
it easy to stack two high. The wheels of the top unit ‘nest’ in
the indentations of the bottom unit to provide stability. It is
recommended the units are properly secured for transport.
The Phoenix R175 must always be upright when transported
by vehicle. It may be tipped onto its handle and back for
loading and moving by hand.
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your Phoenix R175 dehumidifier.
• It is designed to be used
INDOORS ONLY.
• If used in a wet area, plug it into a
GROUND FAULT
INTERRUPTER
.
•
DO NOT
use the Phoenix R175 as a bench or table.
• It must always be used in the upright position.
Figure 1: Stacked
Phoenix R175