8 Service Parts

Item 

Description 

Qty 

Part No.

1  

Top Cover 

1  

4026977

2  

Top Cover Hinge  

2  

4026978

3  

Top Cover Catch  

1  

4026979

4  

Hex Bolts, 1/4”–20 x 4”  

1154019

5  

Hex Bolts,  1/4”–20 x 1.75”  

2  

1154014

6  

Handle Assembly  

1  

4027381

7  

Wheel, 12”  

2  

4026304

8  

Cotter Pin  

2  

1284404

9  

Hub Cap, Wheel 

1  

4027137

10  

Filter, 12” x 12” x 1”  

1  

4026315

11  

Hose (1/4” ID x 33’ long)  

1  

4024916

12  

Coupling Body, 1/4” Tube  

1  

4026306

13  

Coupling Insert, 1/4” Tube  

1  

4026986

14  

Cord  

1  

4032297

15  

Control Board  

1  

4026763

16  

Capacitor, Compressor, 45 μF  

1  

4033032-05

17  

Capacitor, Impeller, 7.5 μF  

1  

4033031-04

18 

Thermistor  

1  

4031279

Items listed are not shown

Description  

Qty  

Part No.

Compressor  

1  

4029168

Evaporator Coil  

1  

4028234

Condenser Coil  

1  

4028235

Accumulator  

1  

4028297

Condensate Pump  

1  

4034582-01

Float Safety Switch  

1  

4034374

Impeller, Air Mover  

1  

4026360

Exhaust Grill  

1  

4026308

Wire Duct Collar  

1  

4026309

Impeller Plate Bolt  

4  

1154006

Specifications subject to change without notice.

Summary of Contents for R175

Page 1: ...idifiers of equal size Energy Efficiency Removes 92 pints at AHAM while drawing only 6 3 amps Patented Bypass Technology 230 CFM More processed air speeds drying and provides superior static pressure for ducting More Grain Depression Drier from an LGR gets your jobs drier quicker Focused Airflow Patent focused outlet directs air downward across the wet surface Multiple Ducting Options 12 intake 10...

Page 2: ...ar 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 33 high x 20 wide x 20 deep Weight 105 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and doors are closed to the outside and seal off the wet area fr...

Page 3: ...reases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will show the accumulated hours Press the POWER button again to turn the dehumidifier off The display will also power off 3 7 PURGE Button During normal operation ...

Page 4: ... drain 2 Plug in the unit but do not turn it on 3 Remove the air filter Slowly pour a pint of the chemical through the top so that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R175 with its high pressure refrigerant system and high ...

Page 5: ...gure 5 Refrigeration system Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air f...

Page 6: ...ma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom plate to the lower housing 3 Disconnect the impeller leads 4 Remove the four screws holding the impeller to the bottom plate 5 Reassemble the new impeller usi...

Page 7: ...U 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL 8 RUN CAPACITOR RUN CAPACITOR BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 9 Wiring diagram 7 Wiring Diagram ...

Page 8: ...33 long 1 4024916 12 Coupling Body 1 4 Tube 1 4026306 13 Coupling Insert 1 4 Tube 1 4026986 14 Cord 1 4032297 15 Control Board 1 4026763 16 Capacitor Compressor 45 μF 1 4033032 05 17 Capacitor Impeller 7 5 μF 1 4033031 04 18 Thermistor 1 4031279 Items listed are not shown Description Qty Part No Compressor 1 4029168 Evaporator Coil 1 4028234 Condenser Coil 1 4028235 Accumulator 1 4028297 Condensat...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R175 Dehumidifier part is repaired...

Reviews: