9/13
4.2 Opening with the super code
If the opening code is lost or the blocking period is active, the lock can be opened with the super
code.
Button
Signal
Description
6sec
Start super code opening
Super code
3sec
Open
Error
4.3 Resetting the opening code by means of the super code
If the opening code is lost, this can be reset with the super code.
In opened lock condition
Button
Signal
Description
6sec
3sec
3sec
Start reset
Super code
Super code
Confirm and close
Changed
Error
After a successful reset, the opening code is set to
and must now be
changed again.
*
1 1 1 1 1 1 1
*
0
1 1 1 1 1 1 1
0
1 1 1 1 1 1 1
*
1 1 1 1 1 1
DS4650 Millenium Duplex Instructions