background image

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER

INSTALLATION INSTRUCTIONS

19mm Particle

board spacer

Floor joist

Floor board

Option B 

  

6

 

3

  

     

PVC Tube

Copper or flexible hose

with G 1/2” Female

connectors.

135 SQUARE 

(APPROX.)

100mm 

deep

1

  Recommended pit to be cast in concrete.

Option A 

8

9

For minor adjustment, rotate and adjust 

the Mixer Assembly to desired position. 

Fasten the Grub Screw to secure the 

Mixer Assembly.

Push Down the Cover Plate over the 

Mount Plate gently. 

www.phoenixtapware.com.au   

FLOOR MOUNTED BATH MIXER

 

IN0162_revA

7

Grub Screw

SAFETY WARNING

Do not use the spout to support yourself when 

entering or exiting the bath. Excessive force 

may cause the spout to break away from the 

body and is not covered by warranty

Connect hot and cold 

hoses to the Inlet Body 

G 1/2” inlet connectors. 

Tighten firmly.

2

4

5b

5a

Fasten Inlet Body to Mount 

Plate with 4 x M8 counter-

sunk screws.

Tighten firmly.

x2

TEST AND CHECK 

FOR LEAKS

Place Protective Cover over 

Inlet Body and fasten with 4 

x M8 screws provided.

Tile up to 

Protective Cover

REMOVE PROTECTIVE 

COVER FROM TILED 

FLOOR.

Gently slide Dress Cover

up Mixer Body.

Screw Mounting Flange into 

Mixer Body. Tighten firmly.

Use Special Spanner 

provided to tighten M15 

connectors to Inlet Body

Use M8 screws to secure 

Floor Mixer to Inlet Body.

Tighten Firmly.

Locate Mounting Plate 

over cast pit and 

secure with M10 

Dynabolts provided.

Tighten firmly.

Ensure Inlet hoses are 

fed through opening in 

the Mounting Plate.

FEED HOSES

THROUGH

OPENING

Dress Cover

Mounting Plate

Inlet Body

M15 Connectors

Timber Floor Installation

Copper or flexible hose

with G 1/2” Female

connectors.

WATER SUPPLY REQUIREMENTS

Maximum hot water

temperature

75

550 KPa Max.

150 KPa Min.

Recommended Working

Pressure

Note: 

-If the pressure exceeds or is likely to exceed 550kpa, 

an approved pressure limiting device must be 

installed.

- Flush out all pipe work prior to installation.

- If the water temperature exceeds 75

°

C, an approved 

tempering valve must be fitted.

- Installation should comply with Australian standard 

AS3500.1 or relevant local authority requirements.

Failure to comply with the above may void all 

warranties.

Maintenance and Care

-Chrome plated surfaces should be cleaned with mild 

liquid detergent or soap and water. 

-

Do not

 use cream cleaners or citrus based cleaning 

products, as they are abrasive.

-Use of unsuitable cleaning agents may damage the 

surface. Any damage caused in this way will not be 

covered by warranty.

Installation Instructions

Use M15 Brass 

Inserts supplied for 

testing.

Summary of Contents for VIVID SLIMLINE VS745 CHR

Page 1: ...STYLISH PREMIUM FINISH PHOENIX WARRANTY CONTEMPORARY DESIGN MATCH WITH VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE FINISH VS745 CHR CHROME ...

Page 2: ...TION TYPE N A MATERIAL BRASS AVAILABLE FINISHES CHROME MATTE BLACK WELS RATING N A FLOW RATE MAX FLOW TEMPERATURE RATING MIN 1 MAX 75 PRESSURE RATING MIN 150 KPA MAX 500 KPA WARRANTY 15YEAR REPLACEMENT CARTRIDGE 7YEAR REPLACEMENT PRODUCT OR PARTS 1YEAR REPLACEMENT PARTS OR PRODUCT LABOUR CARTON SIZE OUTER BOX SIZE OUTER BOX QUANTITY CARTON WEIGHT OUTER BOX WEIGHT WATERMARK LICENCE 130 30 40 71 240...

Page 3: ...EW M5X6 27 O RING 24 SCREW CAP 28 O RING 25 MIXER LEVER PIN 29 SPOUT BEARING 26 O RING 1 UPPERTUBE ADAPTER 2 FLOOR MIXERTUBE 3 MOUNTING PLATE 4 M15 FLEXIBLE HOSE 5 FLOOR INLET BODY 6 THREADED INSERT 7 FLOOR MIXER COVER 130MM 11 HOSE EXTENSION 8 HEX BOLT M8X25 12 SIDE LEVER MIXER BODY 9 O RING 13 25MM CARTRIDGE 10 SCREW 17 19 18 14 29 12 25 20 24 21 22 13 4 1 11 10 2 7 8 3 5 27 24 23 23 9 6 16 15 ...

Page 4: ...ghten firmly Use Special Spanner provided to tighten M15 connectors to Inlet Body Use M8 screws to secure Floor Mixer to Inlet Body Tighten Firmly Locate Mounting Plate over cast pit and secure with M10 Dynabolts provided Tighten firmly Ensure Inlet hoses are fed through opening in the Mounting Plate FEED HOSES THROUGH OPENING Dress Cover Mounting Plate Inlet Body M15 Connectors Timber Floor Insta...

Page 5: ...es to outlet of tap e g water filters Non installation of flow regulated check valve for hand showers Products used for incorrect applications non potable water etc Damage as a result of obstructions due to inadequate flushing of system before use Services repairs or with non standard replacement parts previously undertaken without Phoenix s written approval Damage to finishes by adhesives sealant...

Page 6: ...t fittings and fixtures is not accessible TAPWARE AND ACCESSORIES Care and cleaning Instructions Under no circumstances should you install tapware using acetone silicones Never use harsh detergents citrus based cleaners or abrasive cleaners as these will scratch the surface Where your tapware remains dry in use a soft cloth can be used to remove surface dust Alternatively a wipe over with warm soa...

Reviews: