DO NOT use mirrors or 

magni

ers to concentrate 

sunlight onto the module. 

DO NOT lift or move the 

module by holding the 

junction box or cable

.

DO NOT expose the back of 

the module to direct sunlight.

 

DO NOT drill holes in the frame.

DO NOT install or handle 

module in wet or strong windy 

conditions.

DO NOT use module near 

equipment or in places where 

flammable gases may be 

generated or collected.

Insulated gloves must be worn 

while handling the module and 

during the installation.

DO NOT wear metal ornaments 

while handling the module or 

during the installation.

DO NOT place anything on 

the module or press on the 

module surface. 

DO NOT drop the module or 

allow objects to fall on the 

module. 

DO NOT paint the module 

or attach anything on to 

the back of the module. 

DO NOT attempt to disassemble 

the modules, and do not remove 

any attached nameplates or 

components from the module.

Rated Power 

Tolerance 

Rated Power Voltage

Open C

ircuit

Tolerance 

Rated Power Voltage

Rated Power 

National 

Power

Module (IEC)

Rated Power 

Tolerance 

Rated Power Voltage

Open C

ircuit

Tolerance 

Rated Power Voltage

Rated Power 

National 

Power

Module (IEC)

ted Power 

Rat

Tolerance

To

d P

R t

Module (IEC)

Rated Power 

Tolerance 

Rated Power Voltage

Open C

ircuit

Tolerance 

Rated Power Voltage

Rated Power 

National 

Power

Module (IEC)

01

Rated Power 

Tolerance 

Rated Power Voltage

Open C

ircuit

Tolerance 

Rated Power Voltage

Rated Power 

National 

Power

Module (IEC)

Stability / Reliability / Creativity

IMPORTANT SAFETY GUIDE

This manual contains information regarding product identification and the safe installation 
and maintenance of photovoltaic modules (hereafter referred to as “module”) supplied by 
PHONO SOLAR TECHNOLOGY CO., LTD. (hereafter referred to as “PHONO SOLAR”).  The 
term “module” can be interpreted as a single module or multiple modules depending on 
the context.
Installers must already be familiar with the mechanical and electrical requirements for a 
photovoltaic system. Installers must also read this manual carefully prior to installation. We 
recommend that you keep this manual in a safe place for future reference and in case of 
future sale or disposal of the module.

1.1  General Safety

 The installation of a photovoltaic system requires specialized skills and knowledge and 

must only be carried out by licensed/qualified persons.

 Installers should assume all risks of injury and do everything to avoid potential damages 

and  risks  that  might  occur  during  installation,  including  but  not  limited  to,  the  risks  of 
electric shock.

 PHONO SOLAR modules do not need special cables for connection. All of the modules 

have permanent junction boxes, cables and connectors.

 Do not use mirrors or magnifiers to concentrate sunlight onto the modules.
 The modules generate DC electrical energy from sunlight. They are designed for outdoor 

use and can be mounted onto frames on rooftops or in the ground etc.

 Do not paint the module or attach anything on to the back of the module.
  Do  not  attempt  to  disassemble  the  modules,  and  do  not  remove  any  attached 

nameplates or components from the modules.

1.2  Handling safety 

 When handling the module insulated gloves must be worn.
 Inappropriate transportation and installation may break the module.
 Do not lift or move the module by holding the junction box or cable.
 Do not place anything on the module or press on the module surface.
 Do not drop the module or allow objects to fall on the module.
 Do not expose the back of the module to direct sunlight.

Summary of Contents for F Type module

Page 1: ...lation Manual UL Phono Solar Technology Co Ltd Address No 1 Xinghuo Rd Nanjing Hi tech Zone Nanjing China Tel 86 25 5863 8000 Fax 86 25 5863 8009 E mail support phonosolar com Website www phonosolar c...

Page 2: ...1 IMPORTANT SAFETY GUIDE 2 PRODUCT IDENTIFICATION 3 MECHANICAL INSTALLATION 4 ELECTRICAL INSTALLATION 5 GROUDING 6 MAINTENANCE 7 DISCLAIMER OF LIABILITY CONTENTS...

Page 3: ...aic modules hereafter referred to as module supplied by PHONO SOLAR TECHNOLOGY CO LTD hereafter referred to as PHONO SOLAR The term module can be interpreted as a single module or multiple modules dep...

Page 4: ...n be used to cover the modules Only use licensed qualified insulated tools The frame of the modules may be grounded according to local regional and state safety and electrical standards Only Balance o...

Page 5: ...posed between the two metals When grounding the module frames stainless steel hardware must also be used Note2 In environments where ammonia is present Phono Solar PV modules must be installed under t...

Page 6: ...U Type 1640mm 992mm 35 40 45mm DIAMOND Series ONYX Series T Type 1956mm x 992mm x 45 50mm DIAMOND Series ONYX Series Module Frame Mounting Rail M8 Screw Split Washer M8 Bolt M8 Nut Flat Washer Mounti...

Page 7: ...ility Reliability Creativity B B 410 490mm B B A A 300mm Mounting rails may run perpendicularly or parallel to the long side frame A A Mounting rails may run perpendicularly or parallel to the long si...

Page 8: ...s will void the PHONO SOLAR product warranty 3 4 When installing a module on a pole ensure that the pole and mounting rail can withstand anticipated local winds The pole must be installed on a hard ba...

Page 9: ...ranty and shall not extend beyond the ten years period set forth herein This Limited Product Warranty does not warrant a specific power output which shall be exclusively covered under clause 2 hereina...

Page 10: ...ars from the date of delivery by Phono Solar to the first buyer any Product exhibits a power output less than 80 of the minimum Peak Power at STC 1 as specified as of the Phono Solar s product label p...

Page 11: ...st extent permitted by law Phono Solar shall have no responsibility or liability whatsoever for damage or injury to persons or property or for other loss or injury resulting from any cause whatsoever...

Page 12: ...ation of 1000 W per m2 and c a cell temperature of 25 degree centigrade at right angle irradiation The measurements are carried out in accordance with IEC 61215 as tested at the connectors or junction...

Reviews: