7 Graphical User Interface (GUI)
7.2.1
Exposure
This tab contains exposure settings.
Figure 7.11: MV-D1024E-160 exposure panel
Exposure
Exposure time [ms
:] Configure the exposure time in milliseconds.
Constant Frame Rate:
When the Constant Frame Rate (CFR) is switched on, the frame rate
(number of frames per second) can be varied from almost 0 up to the maximum frame
rate. Thus, fewer images can be acquired than would otherwise be possible. When
Constant Frame Rate is switched off, the camera delivers images as fast as possible,
depending on the exposure time and the read-out time.
Frame time [ms
:] Configure the frame time in milliseconds. Only available if Constant Frame
Rate is enabled. The minimum frame time depends on the exposure time and readout
time.
Information
The Information properties provide information about the acquired images.
Image Counter:
The image counter is a 24 bit real-time counter and is incremented by 1 for
every new image.
Missed Trigger Counter:
This is a counter for trigger pulses that were blocked because the
trigger pulse was received during image exposure or readout. In free-running mode it
counts all pulses received from interface trigger or from I/O trigger interface.
Status Line:
The status line replaces the last line of an image with image information.
To update the value of the information properties, click on the Update-Button; to reset the
properties, click on the Reset-Button.
76
Summary of Contents for CameraLink MV-D1024E-160
Page 1: ...User Manual MV D1024E CameraLink Series CMOS Area Scan Cameras MAN028 03 2008 V1 3...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started CameraLink 12...
Page 20: ...3 Product Specification 18...
Page 46: ...4 Functionality 44...
Page 94: ...9 Warranty 92...
Page 96: ...10 References 94...
Page 100: ...11 Pinouts 98...