( 0 , 0 )
( 1 3 1 1 , 1 0 8 1 )
M
R O
I 0
R O
I
M
R O
I 2
M
R O
I 1
Figure 4.27: Decimation and MROI
The image in Fig. 4.28 on the right-hand side shows the result of decimation 3 of the image on
the left-hand side.
Figure 4.28: Image example of decimation 3
An example of a high-speed measurement of the elongation of an injection needle is given in
Fig. 4.29. In this application the height information is less important than the width
information. Applying decimation 2 on the original image on the left-hand side doubles the
resulting frame to about 7800 fps.