7 Hardware Interface
Fig. 7.17 shows an example of how to connect a flash light and a trigger source to the camera
using star-wiring. The trigger in this example is generated from a light barrier. Note how the
power and ground cables are connected to the same power supply.
P
o w e r S u p p l y
+
-
C
a m
e r a
F l a s h
M a c h i n e V i s i o n
S y s t e m
P C
E t h e r n e t D a t a C a b l e
S T R
+
-
C A M _ P W
R
C A M _ G N D
I S O _ O U T
I S O _ P W
R
I S O _ G N D
I S O _ I N
S t a r t P o i n t
+
-
L i g h t B a r r i e r
Figure 7.17: I/O wiring using star-wiring example
.
96 of 127
MAN075 05/2017 V1.0