8.11 PLC Settings
8.11.3
PLC Settings for A/B Trigger from differential inputs
This settings connects the ISO_INC differential inputs to the A/B camera inputs. ISO_INC0 is
mapped to the A signal and ISO_INC1 to the B signal, see Table 8.2 (the visibility in the
PF_GEVPlayer must be set to
Guru
for this purpose).
The AB Trigger feature is not available on all camera revisions, see Appendix B
for a list of available features.
Feature
Value
Category
TriggerMode
On
AcquisitionControl
TriggerSource
ABTrigger
AcquisitionControl
PLC_I2
Line2
<PLC>/SignalRoutingBlock
PLC_I3
Line3
<PLC>/SignalRoutingBlock
PLC_Q6_Variable0
PLC_I2
<PLC>/LookupTable/Q6
PLC_Q6_Operator0
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable1
Zero
<PLC>/LookupTable/Q6
PLC_Q6_Operator1
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable2
Zero
<PLC>/LookupTable/Q6
PLC_Q6_Operator2
Or
<PLC>/LookupTable/Q6
PLC_Q6_Variable3
Zero
<PLC>/LookupTable/Q6
PLC_Q7_Variable0
PLC_I3
<PLC>/LookupTable/Q7
PLC_Q7_Operator0
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable1
Zero
<PLC>/LookupTable/Q7
PLC_Q7_Operator1
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable2
Zero
<PLC>/LookupTable/Q7
PLC_Q7_Operator2
Or
<PLC>/LookupTable/Q7
PLC_Q7_Variable3
Zero
<PLC>/LookupTable/Q7
Table
8.2:
PLC
Settings
for
A/B
Trigger
from
differential
inputs
(<PLC>
=
in
category
IPEngine/ProgrammableLogicController)
.
MAN075 05/2017 V1.0
109 of 127
Summary of Contents for MV1-D2048-3D06 series
Page 10: ...1 Preface 10 of 127 MAN075 05 2017 V1 0...
Page 12: ...2 Introduction 12 of 127 MAN075 05 2017 V1 0...
Page 26: ...3 How to get started 3D GigE G2 26 of 127 MAN075 05 2017 V1 0...
Page 32: ...4 Product Specification 32 of 127 MAN075 05 2017 V1 0...
Page 66: ...5 Functionality 66 of 127 MAN075 05 2017 V1 0...
Page 82: ...6 Precautions 82 of 127 MAN075 05 2017 V1 0...
Page 120: ...12 Support and Repair 120 of 127 MAN075 05 2017 V1 0...
Page 122: ...13 References 122 of 127 MAN075 05 2017 V1 0...