7 Hardware Interface
7.6.2
Single-ended Inputs
ISO_IN0 and ISO_IN1 are single-ended isolated inputs. The input circuit of both inputs is
identical (see Fig. 7.4).
Fig. 7.6 shows a direct connection to the ISO_IN inputs.
In the camera default settings the PLC is configured to connect the ISO_IN0 to
the PLC_Q4 camera trigger input. This setting is listed in Section 8.11.2.
I
S O _ G N D
I S O _ G N D
I S O _ V C C
e n h a n c e d
P o w e r F E T
4 . 7 V
1 0 k
I S O _ I N 0
C a m
e r a
7
1 2 p o l . H i r o s e
C o n n e c t o r
I S O _ G N D
1 2
Y O U R _ G N D
Y O U R _ G N D
I n p u t V o l t a g e
M a x . + 3 0 V D C
M i n . - 3 0 V D C
+
Figure 7.6: Direct connection to ISO_IN
Fig. 7.7 shows how to connect ISO_IN to TTL logic output device.
I
S O _ G N D
I S O _ G N D
I S O _ V C C
e n h a n c e d
P o w e r F E T
4 . 7 V
1 0 k
I S O _ I N 0
C a m
e r a
7
1 2 p o l . H i r o s e
C o n n e c t o r
I S O _ G N D
1 2
Y O U R _ G N D
Y O U R _ G N D
C o n t r o l L o g i c
&
Y O U R _ V C C
+
+
Figure 7.7: Connection to ISO_IN from a TTL logic device
.
90 of 127
MAN075 05/2017 V1.0
Summary of Contents for MV1-D2048-3D06 series
Page 10: ...1 Preface 10 of 127 MAN075 05 2017 V1 0...
Page 12: ...2 Introduction 12 of 127 MAN075 05 2017 V1 0...
Page 26: ...3 How to get started 3D GigE G2 26 of 127 MAN075 05 2017 V1 0...
Page 32: ...4 Product Specification 32 of 127 MAN075 05 2017 V1 0...
Page 66: ...5 Functionality 66 of 127 MAN075 05 2017 V1 0...
Page 82: ...6 Precautions 82 of 127 MAN075 05 2017 V1 0...
Page 120: ...12 Support and Repair 120 of 127 MAN075 05 2017 V1 0...
Page 122: ...13 References 122 of 127 MAN075 05 2017 V1 0...