ANNEX A: MECHANICAL AND ELECTRICAL RATINGS
Standard Test Conditions are: irradiance of 1 kW/m
2
, AM1.5 spectrum, and cell temperature of 25°C (77°F). The
electrical characteristics are respectively within ±10 percent or [0; +5W] of the indicated values for Isc, Voc and
Pmax. Specifications are subject to change without notice.
Table A: Specifications for PW-series photovoltaic modules under STC
PW2350 UL
Typical power (Pmax)
W
220
225
230
235
240
Voltage at typical power (Vmp)
V
29.8
29.7
29.8
29.9
29.9
Current at typical power (Imp)
A 7.50
7.69
7.75
7.86
8.03
Open circuit voltage (Voc)
V
37.1
37.1
37.2
37.2
37.3
Short circuit current (Isc)
A
8.23 8.28 8.33
8.38
8.45
Power tolerance
W
0/+5
Maximum system voltage
V
1000
Maximum series fuse rating
A
15
PW2500 UL
Typical power (Pmax)
W
230
235
240
245
250
Voltage at typical power (Vmp)
V
29.9
30.1
30.2
30.3
30.4
Current at typical power (Imp)
A 7.70
7.62
7.95
8.09
8.22
Open circuit voltage (Voc)
V
37.1
37.2
37.3
37.4
37.5
Short circuit current (Isc)
A
8.22 8.34 8.46
8.61
8.74
Power tolerance
W
0/+5
Maximum system voltage
V
1000
Maximum series fuse rating
A
15