Clamping
on long
side frame
Use 4 clamps on the long side, the allowed
range depends on the module type.
Mounting rails may run perpendicularly or
parallel to the long side frame.
Use 4 clamps on the long side, the allowed range
depends on the module type.
Mounting rails may run perpendicularly or
parallel to the long side frame
Authorized range for clamping as a function of model type:
Model type
A1 range (mm)
B1 range (mm)
A2 range (mm)
PW2350 UL
PW2500 UL
240 – 410
340 – 410
200 – 250
PW2850 UL
PW3000 UL
340 – 550
410 – 490
200 – 250
C.2 MOUNTING METHOD B: INSERTION SYSTEMS
The mounting method has been qualified by EDF ENR PWT and certified by CSA.
Insertion methods will vary and are dependent on the mounting structures. Follow mounting guidelines
recommended by the mounting system supplier.
Each module must be securely maintained through all its length on two opposite sides. Install and tighten
the insertion profiles to the support structure using the hardware and instructions provided by the mounting
system manufacturer. System designer and installer are responsible for load calculations and for proper
design of support structure.
EDF ENR PWT warranty may be void in cases where improper insertion systems or unsuitable installation
methods are found. When installing insertion profiles, take measures so as:
1.
Not to bend the module frame
2.
Not to touch or cast shadow on the front glass
3.
Not to damage the surface of the frame
4.
To ensure the insertion profiles overlap the module frame by at least
10 mm.
5.
To ensure the module frame (C-shape) overlap the insertion profiles
by at least 15mm.
6.
To ensure insertion profile thickness and tolerances suits module
thickness .