1.0 GENERAL INFORMATION 

This general manual provides important safety information relating to the installation, maintenance and handling 
of CS-series solar modules. System users and professional installers should read this manual carefully and 
strictly follow the instructions. Failure to follow these instructions may result in death, injury or property damage. 
The installation of solar modules requires specialized skills and should only be performed by licensed 
professionals. 
The word "module" or "PV module" used in this manual refers to one or more PW-Series Solar Modules. 
Please retain this manual for future reference. It is recommended to regularly check online for the most updated 
version. 
 

1.1 DISCLAIMER OF INSTALLATION MANUAL 

The Information contained in this manual is subject to change by EDF ENR PWT without prior notice. EDF 
ENR PWT makes no warranty of any kind whatsoever, either explicitly or implicitly, with respect to the 
information contained herein.   
 

1.2 LIMITATION OF LIABILITY 

EDF ENR PWT shall not be held responsible for damages of any kind, including without limitation bodily harm, 
injury and property damage, relating to module handling, system installation, or compliance or non-compliance 
with the instructions set forth in this manual. 
 

2.0 SAFETY PRECAUTIONS 

Warning:

 All instructions should be read and understood before attempting to install, wire, 

operate and/or maintain the module. Module interconnects pass direct current (DC) when 
exposed to sunlight or other light sources. Contact with electrically active parts of the module, 
such as terminals, can result in injury or death, whether the module is connected or 
disconnected. 

Avertissement :

 Toutes les instructions devront être lues et comprises avant de procéder à 

l’installation, le câblage, l’exploitation et/ou l’entretien des panneaux. Les interconnexions 
des panneaux conduisent du courant continu (CC) lorsque le panneau est exposé à la lumière 
du soleil ou à d’autres sources lumineuses. Tout contact avec des éléments sous tension du 
panneau tels que ses bornes de sortie peut entraîner des blessures ou la mort, que le panneau 

soit connecté ou non. 

General Safety 

 

All installations must be performed in compliance with all applicable regional and local codes such as, the 
latest National Electrical Code (USA) or Canadian Electric Code (Canada) or other national or international 
electrical standards.     

 

Wear suitable protection (non-slip gloves, clothes, etc.) to prevent direct contact with 30VDC or greater, 
and to protect your hands from sharp edges during the installation.     

 

Use electrical insulated tools to reduce the risk of electric shock. 

 

Remove all metallic jewelry prior to installation to reduce the chance of accidental exposure to live circuits. 

 

Cover the front of the modules in the PV array with an opaque material to halt production of electricity 
when installing or working with a module or wiring. 

Summary of Contents for PW2350 UL Series

Page 1: ...ax 33 4 74 93 80 40 EDF ENR PWT Soci t par actions simplifi e associ unique au capital de 37 505 000 N 513 281 972 RCS NANTERRE Si ge social 100 Esplanade du G n ral de Gaulle C ur D fense Tour B 9293...

Page 2: ...ling system installation or compliance or non compliance with the instructions set forth in this manual 2 0 SAFETY PRECAUTIONS Warning All instructions should be read and understood before attempting...

Page 3: ...ith an AM1 5 spectrum and cell temperature of 25 C The detailed electrical and mechanical characteristics of EDF ENR PWT crystalline silicon PV modules can be found in table A 2 of this manual see Ann...

Page 4: ...with sharp objects as scratches may directly affect product safety Do not leave a module unsupported or unsecured Do not change the wiring of bypass diodes Keep all electrical contacts clean and dry 5...

Page 5: ...ted together to create a voltage higher than the permitted maximum system voltage even under the worst local temperature conditions Similar electrical performance modules should be connected in the sa...

Page 6: ...op and ensure conductor ampacity complies with local regulations such as NEC 690 8 D Cable protection Secure the cables to the mounting system using UV resistant cable ties Protect exposed cables from...

Page 7: ...ed for Photowatt modules as described below For alternative CSA qualified grounding methods please refer to Annex B Method Bolt Nut with teeth Cup washer When diameter of the grounding holes is 5mm CS...

Page 8: ...lified Clamping on INTERTEK qualified Use appropriate corrosion proof fastening materials All mounting hardware bolt spring washer flat washer nut should be made with stainless steel M6 size for bolti...

Page 9: ...below the module Mounting rails should run parallel to the short side frame Bolting on long side frame Use 4 standard mounting holes long side Mounting rails may run perpendicularly or parallel to the...

Page 10: ...pecifications are subject to change without notice Table A Specifications for PW series photovoltaic modules under STC PW2350 UL Typical power Pmax W 220 225 230 235 240 Voltage at typical power Vmp V...

Page 11: ...r Vmp V 35 8 35 9 36 0 36 1 36 3 Current at typical power Imp A 7 96 8 08 8 19 8 30 8 41 Open circuit voltage Voc V 44 3 44 4 44 5 44 6 44 8 Short circuit current Isc A 8 53 8 64 8 76 8 87 8 97 Power...

Page 12: ...le Once crimped each terminal should be visually checked according to the following points 1 The insulator jacket is correctly crimped in the first collar 2 The conductor core is correctly crimped in...

Page 13: ...r cast shadow on the front glass 3 Not to damage the surface of the frame 4 To ensure the clamps overlap the module frame by at least 5 mm 5 To ensure the clamps overlap length is at least 40 mm Clamp...

Page 14: ...SYSTEMS The mounting method has been qualified by EDF ENR PWT and certified by CSA Insertion methods will vary and are dependent on the mounting structures Follow mounting guidelines recommended by t...

Page 15: ...Pa Downforce load 2400 Pa Uplift load 2400 Pa 2400 Pa Downforce load 4000 Pa Insertion profile on short side frame Use 2 insertion profiles running parallel to the short side frame Use 2 insertion pr...