4.0 UNPACKING AND STORAGE
Precautions and General Safety
Store modules in a dry and ventilated room.
Do not allow children and unauthorized persons near the installation site or storage area
of modules.
Do not transport modules in an upright position.
Unpacking module pallet with care and follow the unpacking steps marked on the pallet. Be careful when
unpacking, transporting and storing the modules.
Do not carry a module by its wires or junction box. Carry a module by its frame with two or more people.
Do not place modules on top of each other.
Do not place excessive loads on the module or twist the module frame.
Do not bow modules under their own weight.
Do not stand, step, walk and/or jump on the module.
Do not drop or place objects on the modules (such as tools.)
Do not mark the modules with sharp instrument. Particular attention should be taken to avoid module
backsheet to come in contact with sharp objects, as scratches may directly affect product safety.
Do not leave a module unsupported or unsecured.
Do not change the wiring of bypass diodes.
Keep all electrical contacts clean and dry.
5.0 MODULE INSTALLATION
Precautions and General Safety
Before installing modules, contact the appropriate authorities for site, installation and
inspection permission and requirement.
Check applicable building codes to ensure that the construction or structure (roof,
facade, support, etc.) can withstand the module system load.
When installing the modules, please ensure the assembly is mounted over a fire resistant roof covering rated
for the application. EDF ENR PWT modules have been listed as Class C according to UL790 standard.
The fire rating of this module is valid only when mounted in the manner specified in the
mechanical mounting instructions.
CAUTION: In any case DO NOT STAND OR STEP on the modules, as localized high
loads may induce severe micro-cracks at the cell level, which in turn may compromise
module reliability. Failure to comply with above caution will void EDF ENR PWT
warranty.
Environmental conditions
The module is intended for use in general open climates, as defined in IEC 60721-2-1: Classification of
environmental conditions Part 2-1: Environmental conditions appearing in nature - temperature and
humidity.
Do not install modules near naked flames or flammable materials.
Do not expose modules to artificially concentrated light sources.